Crematorium for Small Animals Gear


Basic Info.

Model NO.:cost of an incinerator with 20kg/hr loading rate
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste may use in this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, reside waste. Prohibit any explosive and radiation substance, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity  A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time daily to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time plus time for feeding waste. Actual combustion time daily is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Ordinarily, we proposition little laboratory, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, please compute the waste output capacity around 2kgs per individuals every day. If there are 200 sickbed in the clinic, that's imply you need one incinerator capability around 400kgs daily, change to capacity per hour is approximately 30-40 kgs per hour. According the performance time every day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Meeting and Testing  A: We supply all documents and incinerators simple to setup and functionality. Small scale medical incinerator, smart ash incinerator, 30 pound per hour-incinerator, animal incinerator for sale, incinerators, incinerators for sale, Customer can send individuals visit our factory to learn operation and installation. Generally, we don’t send engineer to neighborhood site or even ask. The dispatch cost is additional according to order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi level.  The second combustion chamber: 1000-1200 centi level.  PLC mode according to order and model. 

One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand threat of medical waste to safeguard worker self with essential protection component. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items Specification
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

heater for medical waste



heater for medical waste.Controlled air clinical waste incinerator produced for incineration of bio-medical waste created at a blood-processing center. The waste to be handled mainly includes bio-waste (i.e. physical fluids), transmittable and likewise polluted products such as syringes, needles, as well as other clinical waste (i.e. silicon rubbers, plastic, fabrics, papers, packs, and so on). a diesel terminated clinical waste heater with an ability of 300Kg/hr. to be installed at a waste disposal website away from booming places.

Demands
1) Possible Buyer or Manufacturer ISO 9001 Licensed
2) Appreciating worldwide exhaust requirements
Electric attributes
3) A 230V, 60Hz single-phase electric resource.
4) Protections against over-voltage as well as over-current line problems.
5) Conformity with ideal Ghanaian standards as well as additionally policies.
Functional characteristics
6) Two-stage incineration with dual chamber combustion.Incinerator with Oil Heating unit.
Need Quantity – – – – 1 full Unit/ Establish
Type of Materials To be Lost –– – – Strong Waste Burner Capacity – – – – 0.2 Kw( 200 watts) Ability –– – 2 load daily Oil Container capability of Burner – – – – 300 Lit Oil pump ability – – – – 0.4 Kw (400 watts ). scientific waste Incinerators for melting health care facility waste so we are looking for a resource



Small Waste Incinerator


Basic Info.

Model NO.:small scale incenaration
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on sequence * High temperature, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock. 

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Application Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Required Specs for Mobile Burner



Functional Abilities

  • PROCESS MINIMUM 1 TON PER DAY
  • OPERATED WITH LIMITED TRAINING
  • REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING
  • COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
  • ABILITY TO BURN WASTE LUBRICANTS (POL)
  • HANDLE ORGANIC SOLIDS (TO INCLUDE RMW)
  • DEPLOYABLE
  • MOBILE
  • 24 HRS OF CONTINUOUS USE
  • AUTOMATIC LOADING SYSTEM
  • AUTOMATED ASH REMOVAL SYSTEM
  • GAS SCRUBBING SYSTEM
  • 95% REDUCTION OF SOLID WASTE
  • OPERATE OFF DIESEL OR FUEL OIL
  • CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
  • ABLE TO TAKE ALL COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, WOOD
  • NO PRE-TREATMENT OF WASTE REQUIRED
  • FIVE (5) YEAR COMPONENT WARRANTY

Technical Specs

  • OPERATION MANUAL AND TRAINING MANUAL FOR EACH INCINERATOR
  • SET UP AND INSTALLATION INSTRUCTION MANUALS
  • BLUE PRINT/ SCHEMATIC PROVIDED THAT OUTLINES THE PHYSICAL DIMENSIONS OF THE 20’ INCINERATORS
  • INCINERATORS COMPOSED WITH HEAVY DUTY WELDED CONSTRUCTION
  • OPERATED AND TRANSPORTED IN 20’ INCINERATORS (CONTAINERS)
  • FULL FRONT AND OPTIONAL REAR ACCESS
  • PRIMARY / SECONDARY TEMPERATURE CONTROLS



CLOVER focussed on containment of Ebola

Containerized Incinerator 2 Containerized Incinerator 1 - 1

The past few months have been a very busy time for CLOVER. The outbreak of Ebola in West Africa has resulted in all of the Global aid organisations contacting CLOVER to support them in getting the necessary equipment to the effected regions.

waste incineration technologey manufacturer clover medical limited, incinerator in china,

waste incineration technical provider in german, incinerator container,

The United Nations, UNOPS and local agents are now in constant contact with CLOVER in their attempts to stop the potential of further contamination by destroying medical waste streams at the source.

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions. CLOVER have a wide range of medical Incinerators that allow for small batches of 10kg up to an impressive 600kg per hour. Many years of research and development has made CLOVER a company that is globally renowned and respected and are the go to company for a diverse set of organisations when such problems arise. The quality of our China manufactured product is of the highest standard and the warranties reflect the performance and life cycle of our Incinerators. All of the organisations have shown great interest in the Innovative and high performing mobile model that gives both performance and mobility, we currently have a large number of this model on route to the region as we speak.

incinerator-for-ebola

small size incinerator

small incinerator

We are now talking to the individual countries about their ongoing requirements to support the process of  this virus being contained and eventually eradicated. Our range of mobile incinerators are the ideal solution to enable mobile and instant waste management to areas that are restricted due to infrastructure and remoteness.

CLOVER will continue to strive on many fronts to ensure that our product range is the best in the Incinerator market and part of that process is the ability to service markets and disaster areas in the quickest possible time. This we will do with the utmost priority in servicing all of the Aid organisations and government agencies to win the battle against Ebola.

We urge everyone who can assist to do their utmost to help and support the people of West Africa, in the belief of bringing this problem to an end, Join us on our Social Media platforms to support the Ebola effort.

If you have any immediate requirements for one of our medical Ebola incinerators please contact with us know:

Website: www.clover-incinerator.com    Email:    sales@clover-incinerator.com   Tel:  +86-25-8461 0201

animal incinerator china


Medical Waste Shredder

 

 Capacity: Should be 150 liters.

 Should be capable to shred up to 100 liters of the treated waste.

7

 The technology should be capable to treat hospital waste including sharps like needles,

lancets, scalpels and soft materials like bandages.

 Must render the waste to be unrecognizable.

Following accompanying documents must be supplied with the treatment system and shall

be available at the Site:

  1. Operation instructions (including process description.
  2. Loading and maintenance procedures.
  3. Short-form of operation and loading procedures.
  4. ASTM International (ASTM):

 

C401 91 (2005) Standard Classification of Alumina and Alumina-Silicate Castable Refractories

 

C612 04       Mineral Fiber Block and Board Thermal Insulation

 

  1. National Fire Protection Association (NFPA):

 

70 07     National Electrical Code

82 04     Incinerators and Waste and Linen Handling Systems and Equipment

 

  1. Underwriters Laboratories (UL):

 

50 07…  Enclosures for Electrical Equipment

 

 

PART 2 PRODUCT

 

2.1  INCINERATOR INSTALLATION

 

  1. The incinerator shall consist of a low temperature carbonizing changer (primary chamber) in which the waste

components are converted into gas by heat which is produced through incomplete combustion as the result of a deficiency

of air, and a gas reactor (thermal reactor) in which the gas is burned with a controlled excess of air.