Waste Incinerators From Chinawaste, Incinerators


Product Description

Incinerator is a incineration equipment, direct fire squander by gasoline fuel or oi fuel. As distinct circumscription, incinerator could be termed many words as below: 

Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant.  All over the world, in most nations, individuals anti incinerator because the incinerator will produce a large Dioxin from the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological characteristics. China ecological incinerator manufacturers, China horse cremation incinerators, China incenarators for sale, China incinerators company, China incinertor inkjet version yd 500, Dioxins can be released into the environment through woods fires, backyard burning of trash, certain industrial activities, and residue from beyond business burning of waste. Dioxins break down very slowly and previous releases of dioxins from the man-made and natural sources still exist from the surroundings. Anyhow, we have to remind that, this is big scale incineration pant, generally greater than 30 ton every day. This is a societal problem, to examine and indicate ways in various angles from the public, government, economic development, environmental protection, technology advancement, etc. 

So, why we use incinerator?  To begin with, for your medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management.  Second, for human body, pet creature, in most nations and areas, we desire to cremation them.

As previously two rationale but not just above, we nevertheless utilize incinerators. 

the way you can find reasonable incinerator for your local site?  Incinerator isn’t a cheap equipment, generally the small scale version 's price around $5, 000USD per unit and big scale version 's price more than $50, 000USD per unit. So, before purchase one unit incinerator, you need to make clear following items: A, burn what? Incinerator is a incineration equipment, function is fire squander. So what sort of waste that you want to cure?  B, small or big? This based on the waste output daily or the waste volume per feed period, like creature size.  C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil gas version. However, some neighborhood site don't have gasoline supply system.  And other technology products, like power(220V, 380V), waste feed door type, incinerator construction, etc. 

Once you describe these, you can go to find a local or international manufacturers, asking prices, technical specifications and finally purchasing the ideal products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

multiple diesel fuel combustion incinerators

The incinerators to be supplied shall meet the following specifications

  1. ISO certified
  2. Model:   250LA ,multiple diesel fuel combustion chambers
  3. Performance capacity
  • 120Kg/hr GRE 1.25 for HCRW
  • 96Kg/hr GRE 1.25 for general waste.
  • 40Kg/hr GRE 3.00 for plastic
  1. Waste type :   health care risk waste and general waste
  2. Chimney stack:
  • Chimney : 3.5mm mild steel
  • Height from base :11m and if there are buildings within

30m of the incinerator, chimney must extend at least 3m

above the apexes of all the roof of such buildings

  • Diameter of chimney at top :430mm
  • Weight of stack: ±500 Kg
  • Case and stack be painted with 400⁰C heat resistant Black paint
  1. Burners:
  • 1st chamber 850⁰C – 900⁰C
  • 2nd chamber 1000⁰C
  1. Variable speed combustion air blowers
  2. Primary chamber volume ±1.05 cubic metres
  3. Mixing chamber volume ±0.30 cubic metres
  4. Settling chamber volume ±0.89 cubic metres
  5. Weight excluding chimney ±6.400Kg at manufacture
  6. .Firing tools supplied :Hoe ,poker and rake
  7. Dimensions
  • Length                   ±2125mm
  • Width                   ±1890mm
  • Height                   ±2125mm
  • Extra width for burners ± 1000mm
  1. Loading door opening 610 *540mm
  2. Hearth area ±1.19square metres
  3. Description of grate/hearth :A full hearth to be supplied to prevent contaminated
  4. Liquids from flowing into ash pit without being incinerated
  5. Compliance with South African Atmospheric Pollution Prevention Act No.45 of

1965 or equivalent air pollution standards

  1. Documents to be supplied :Operations and maintenance manual and standard

operating procedures (SOPs)

  1. Emission controls:
  • heated refractory screen
  • Low velocity grit settling chamber
  • Stainless steel arrester screen

 

  1. Refractory material :alumina content> 49% and thickness average 102mm
  2. Bake out : to be done over 2-3 days
  3. Materials of constructions
  • Case :5mm mild steel
  • Bracing: heavy angle and channel
  • Hearth: 1550 ⁰C
  • Ashing door: high grade cast iron
  • Loading door 5mm mild steel lined with 1550 ⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
  • Incinerator walls and roof: 1550 ⁰C castable monolithic refractory

 

  1. Temperature: ≥ 90 ⁰C
  2. Insulation to walls: 1000 ⁰C castable insulation
  3. Electricity supply required: 220volt, 15amp single phase
  4. Controls:
  • Draught control: barometer indicator, door operated draught limiter
  • Air supply: built-in forced heated air ducts, primary and secondary (intensifier)
  • Electric: control panel includes-circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer

 

 

Summary of Key Expected Activities/Outputs

  • Replacement of pipes from the tank to the incinerator
  • Covering pipes to protect them bursting in winter
  • Replacement of gauge
  • Incinerator installation
  • Installation report
  • End of contract report

 

 

 

A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE

SPECIFICATIONS OF A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE
1.    Capacity of destruction in weight: 500 kg/h.
2.    It should be able to operate not less than 8 hours/day
3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
4.    Design Specification : Types A, B, C, D, and E of medical waste
5.    “PYROLYTIC” combustion, by controlling the gasification of waste.
6.    The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
7.    It should be able to reduce the volume of wastes by 98%.
8.    It should be able to hold emission in the second burn with gas residence of not less than 2
seconds.
9.    The incineration should be completely free from visible smoke as well as offensive odours.
10.    The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
•    The Temperatures of combustion: Minimum will be 850oC and max 1400oC
•    Post combustion: >1100oC.
11.    The Internal diameter of the Chimney: Ø 400 and its height: 8 m
12.    The Volume of the combustion chamber: 1.200 L
13.    The Dimension of the door for loading in cm: 120×120.
14.    Burner operation should be Automatic On/Off
15.    Fuel : diesel/Gas
16.    The supplier must provide necessary information for the best of the installation This incinerator with “PYROLYTIC” combustion must have:
17.    A combustion chamber of waste:
*    Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch
Load
*    A burner of lighting which the use is limited to the ignition of waste.
*    Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
*    The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on
the outside sheet metal.
*    Composition of the refractory;
•    Refractory concrete :
▪    . Thickness    : ≥100 mm
▪    . Nature: 42% of Al203
•    Insulate in fibrous panels :

▪    . Thickness: ≥75 mm
•    Nature: Calcium silicate.
*    Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
*    Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

18.    A chamber of post combustion of gases
*    A burner of combustion of gases,
*    A device of injection of air allowing a total recombustion of gases,
*    A device of air inlet of cooling of waste gases,
*    A sheath of evacuation of the gases burnt.
*    Carcass in strong sheet steel with support of connection.
*    Composition of the refractory;
•    Refractory concrete :
▪    Thickness    : ≥150 mm
▪    Nature: 65% of Al203
•    Insulate in fibrous panel :
▪    Thickness: ≥85 mm
▪    Nature: Calcium
*    Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
*    A secondary injection of air to ensure perfect oxygen content.
19.    A control box ensuring the complete cycle of combustion.
20.    A Pollution control device connected to the flue chimney must be connected to prevent
unnecessary escape of pollutants

21.    Fan:
*    Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
22.    Controls and regulations:
Control box watertight to dust, including:

*    A switch circuit breaker for each engine (ventilators and burners).
*    A timer with adjustable temporization for the regulation of each burner.
*    A regulator with digital watching for the temperature of combustion.
*    A regulator with digital watching for the temperature of post combustion.
*    Electric box.

21.    The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing.
22.    Process Filtering system : Scruber to be mentionned as optional
23.    Emission Standards Compliance: BS 3316 or équivalent standard
23.    Capacity to treat Plastic: Not less than 40% by weight
24.    CE Manufacturing Compliance: BS EN 746-2-1997

23.    The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
24.    The installed incinerator must bear a one year guarantee.
25.    The supplier shall perform an onsite installation of the incinerator.
25. The technical training of operators will have to be provided and given by a technician from the factory; it will consist of curative and preventive maintenance, and the use of machine, etc

NB.: Civil works and any other related services for the installation and training of operators must be included in the incinerator’s price.

Biomedical Waste Incinerator


Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Alcance de uso:  1. Hospital y clí Nica: Los desechos mé Dicos, quirú Rgicos residuos jeringa, infusió N, Vestidor, Bio-Residuos, Medicina.  2. Masacre Casa y Hospital del animal domé Stico y agrí Cola: Animales muertos, residuos bioló Gicos.  3. Comunidad y de Puertos Marí Timos y la estació N: Residuos urbanos, etc 

Incinerator is a incineration gear, direct fire squander by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be named many words as under: 

Therapy ability: Small scale incinerator, big scale incinerator and incineration pant. 

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator fuel: Gas incinerator, petroleum incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer. 

Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Hospital Incinerator Design


Product Description

Nanjing Clover Medical Technology Co., Ltd..

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hour, up to 6ton per day.  * PLC Control Plane. *according to order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Diesel Fired, Capacity: 50kg Waste Per Hour


Basic Info.

Model NO.:incineration hazardous waste management in italy
Export Markets:Global

Product Description

Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  * New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and components in stock. 

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Clovers incinerators, cocaine incineration, cocaine incinerator, combustion chamber burner. Combustion chamber for gas power plant, combustion chamber of creatures, Dead Animal, Bio-Waste.

Items Specification
YD Model YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Medical Incinerator 10kg/Hour


Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste may utilize within this gear?  A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Remedy capacity  A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t indicate any waste material. The animal/pet combustion speed around 2/3 of average power. 

Clover incinerator utilize time daily to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding squander. Actual combustion time daily is around 16 hours. The life of incinerator involving 5-10 year according to utilize. 

Ordinarily, we proposal small lab, small clinic use capability under 20 kgs per hour. When incinerator use in hospital, then please compute the waste output around 2kgs per people per day. If there are 200 sickbed at the clinic, that's mean you need one incinerator capability around 400kgs per day, switch to power per hour is approximately 30-40 kgs per hour. 300 kg incinerator, animal cremation burners, animal incinerators china, china medical waste incinerator, china+incinerator, hospital incinerator manufacturer, According the performance time per day, waste material, budget, growth, etc, you may use ability from 30-50 kgs per hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Assembly and Testing  A: We supply all documents and incinerators easy to installation and functionality. Client can send people come to our factory to learn operation and installation. Generally, We do not send engineer to neighborhood website or even ask. The dispatch cost is extra according to order. 

Q: Combustion Temperature  A: The very first combustion chamber: 800-1000 centi degree.  The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control manner is common control case. PLC mode according to order and model. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD annually maintenance according model, use scenario. 

One individual can service 02 unit incinerators. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know threat of medical waste to protect worker self with essential security element. 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

High Performance Small Incinerator Plant


Product Description

Pyrolytic incineration specialized is conventional waste treatment way for several decades. All over the planet, in most nations, people anti incinerator because the incinerator will create a sizable Dioxin from the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological features. Dioxins can be released into the environment via woods fires, krakow incinerator job, kwai chung incineration plant, kyrgyzstan waste to power, laboratory scale incinerator supplier, lab crematorium, lab icinerator maker, backyard burning of trash, particular industrial activities, and residue from past business burning of waste. Dioxins break down very slowly and previous releases of dioxins from the man-made and natural resources still exist from the surroundings. Anyhow, we must remind this, that is big scale incineration pant, normally greater than 30 ton every day. This is a societal issue, to examine and indicate ways in various angles from the public, government, economic development, environmental protection, technology advancement, etc. 

YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This gear quality structural for types of site, such as hospital, environmental division, animal cremation agencies, etc.. CLOVER Incinerator supply updated models with double combustion chamber, mix combustion space and smoke filter room with refractory lines, along with the combustion room temperature up to 1200 deg C.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)