Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Application Scope:  1.

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator could be named many words as under: 

Treatment ability: Small scale incinerator, large scale incinerator and incineration pant. 

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator fuel: Gas incinerator, petroleum incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer. 

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Medical Waste Incinerator of 20 kg/hr capacity with dual burner

3 Medical Waste Incinerator of 20 kg/hr capacity with dual burner.Medical Waste Incineration Systems. i’m interested to destroy about 200 kg remains. a Medical Incinerator project for Tehran municipality. Our purpose for this project is to establish a plant in order to incinerate Medical waste with 50 ton/day capacity. a incinerator with 100 kg / hour burning capacity. And it should work on diesel fuel, 2 chamber. Waste management
Incinerator
*External diameter at base 6ft 1.8m
*External diameter at top 4 1/2ft 1.35m
*Internal diameter at base 3ft 0.9m
*Internal diameter at top 3ft 0.9m
*Thickness of wall at base 18cm
*Thickness of wall at top 9cm
*Perpendicular height of wall 4ft
*Height of Iron bars from grate above ground 1ft

Material Required
*Puddle swish
*5 or 6 Iron bars about 4 1/2ft 1.35m long each
*Quantity of large stones for foundation
*2 empty kerosene tins for making vent holes
*2ltrs of coal tar
*2 brushes
*Foundation 1ft-1 1/2ft deep is dug
*Filled with large stones and puddle swish to ground level
*Empty kero tins are next placed into position where the vent holes are to appear
*Wall 1ft high is built with puddle swish
*Iron bars are put in position leaving a space of about 2cm-3cm between the bars 4ft 1.2m to be reached
*Wall plastered smooth.Incinération à haute température pour la destruction complète des déchets contaminés ou dangereux.
Principe de combustion pyrolytique avec brûlage des fumées dans une chambre de post-combustion
Incinérateur double chambre 900°C/1200°C de capacité 30 kg.
Equipé de : 1 brûleur de combustion + 1 brûleur de re-combustion + 1 laveur de fumées. Capacité de destruction horaire
En poids : au moins 30 kg
En volume : au moins 200 litres
Température :
Combustion : 900°C
Post combustion : 1200°C
Puissance des brûleurs
Combustion : au moins 80 KW
Post combustion : 80 KW
Puissance électrique : environ 2 KW
Cheminée :
Section : environ 30×30 cm
Hauteur (minimum) : au moins 8 m
Dimension de la porte de chargement : environ 50X50 cm

eco satisfying burner


50 bed health care centre in addition to additionally would love to have your referral for heater that can properly take care of the lots of 50 mattress hospital.Incinerator for burnable rubbish (newspaper & & & & & & & & all-natural) gadget capability (100/150 lts). Bio Medical Waste Incinerators,

Capability: 50kgs a hr Medical Waste Burner Layout TS50 (PLC) with both choice on Gas (Gas as well as also / or Diesel2 Burners
1 Blower environmentally friendly burner for dropping polyproplylene bags we have 10 lots once a week


BIOGRAPHY WASTE BURNER


50 kg/  hour  capacity incinerators

·        Burning Speed: 50kos/hr

·        Feed Capacity:  150kqs

·        Main Combustion  Chamber:  900 liters

·        Secondary  Combustion  Chamber:  300 liters

·        Mix Combustion  Chamber:  Yes

·        Smoke Filter Chamber:  Yes

·        Feed Mode: Guide

·        Electricity: 0.7Kw

·        Fuel Type: Diesel Oil/ Organic Gas/LPG

·        Internal Dimensions:  120 x 90 x 85cm (main chamber)

·        External  Dimensions:  200 x 160 x 310cm (without  chimney)

·        Burning  Performance:  >98%

small  scale medical waste  incinerators.The necessary burning capacity of those incinerators are 10 kg and 15 kg/hr. The gas oil using for those incinerator is petrol oil.


First Medical Waste Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover

Product Description

YDC incinerator is newest layout for waste treatment, include health care waste, animal cremation and other solid waste. This equipment quality structural for types of website, like hospital, environmental department, animal cremation agencies, etc.. CLOVER Incinerator supply upgraded models with double combustion room, mix combustion chamber and smoke filter room with refractory lines, along with the combustion room temperature up to 1200 deg C.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

incinerators animal


Class 2          Industrial Incinerators

Class 2A:    Commercial

Incinerators for the disposal of waste that contains hazardous, potential hazardous and bio-medical waste where the

operator exceeds 100 Kg/day.

  1. Dimensions: 2.2m(l) x 1.5m(w) x 2.5m(h)
  2. Fully automatic computer multi control system.
  3. Fuel Options- Diesel and natural gas, electricity
  4. Wasted fuel- >12L/h
  5. The incinerator should burn up to 200kg < of waste per hour.
  6. Min.temperature-750癈<
  7. Max.temperature-1000癈<

 

Class 2B:      Small Scale Incinerators for Private Use

Incinerators for the disposal of hazardous, potential hazardous and bio-medical waste where the operator does not

exceed 100 kg/ day.

 

Class 3:  General waste Incinerators

Incinerators for general waste that is non toxic, non hazardous, non medical or does not  contain organic halogens,

i.e., selected customs, police, contraband goods, offices waste, commercial waste  and industrial wastes) where the

operator does not exceed 1 ton/ day.

 

 

STANDARDS, GUIDELINES, CRITERIA, PROCEDURE FOR INSTALLING/OPERATING INCINERATORS

 

No. Parameter     Standards, Guideline, Criteria and Procedure

 

1     Basic Plant Design     An approved plant must have four distinct sections that demonstrate three principles of

Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not

limited to:

 

Overall plant layout.

Feed chamber/ charging   —build by local customer

Primary Combustion Chamber. –yes

Secondary Combustion Chamber. –yes

Particulate Scrubbers—- filter brick chamber included

Acid Gas Scrubbers—none

The stack/ chimney. –yes

2     Feeding And Charging     Controlled hygienic, mechanical or automatic feeding methods have to be used which will

not influence the air temperature in the primary and secondary chambers of the incinerator negatively.

 

No waste is to be fed into the incinerator:

 

  1. Until the minimum temperatures have been reached.—manual feeding

Please  incorporate a mechanical feeder

  1. If the minimum combustion temperatures are not maintained. –yes
  2. Whenever the previous charge has not been completely combusted in the case of batch feeding. –yes

 

  1. Until such time as the addition of more waste will not cause the design parameters of the incinerator to be

exceeded. –yes

 

3     Primary Combustion Chamber The primary combustion chamber must:

 

  1. Be accepted as the primary combustion zone. –yes
  2. Be equipped with a burner/s burning gas/fuel or low sulphur liquid fuels. Other combustion methods will be

judged on merits.

 

  1. Ensure primary air supply is controlled efficiently–yes
  2. Ensure minimum exit temperature is not less than 850oC—800-1000 oC

 

4     Secondary Combustion Chamber (Afterburner). The secondary combustion chamber must:

 

  1. Be accepted as secondary combustion zone. –yes
  2. Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any suitable fuel. –yes


Regenerative organic agriculture could alleviate–or even reverse–the effects of climate change.

incinerators plants

In the process of developing a project, we came across an issue, which is the estimate cost of incinerators plants (capable to destroy chlorinated in an environmental friendly way – please provide cost estimate/price range of incinerator plant).

  1. What kind of waste is to be burned?
  2. In which country the incinerators have to be installed?
  3. What about the amount of waste to be burnt per hour/day/week or per cycle?
  1. Ozone depleting Substances (chlorinated gas, CFC-11/12, HCFC-22 and similar mixtures), POPs (Polychlorierte Biphenyle mainly). Temperature of over 1200C is required.
  2. 150 MT of POPs (PCB) 210 MT of ODS for 3 countries in 2 years.  Therefore it would be good to know  the connection between price and capacity. (starting from 1 t/day for X USD till 10.000 t/day for XXXXUSD)