municipal garbage waste dumping site

In our area and vicinity there are few municipal garbage waste dumping site. We are facing lot of difficulty like foul smell, emmissions of toxic gases and CO2 gases. Since we believe in green energy we wish to convert this waste into power.

municipal garbage waste dumping site
On this context to convert municipal waste to power we happened to visit a plant in Delhi , India where they are handling and burning the wastes to produce power. We saw the process and came to know that the plant was supplied from China.

Since most of the municipal corporations in India have got various dumping yards it will not be ideal to install a central disposal unit  and therefore small plants of this type will be suitable.

HICLOVER Medical Waste Burner in Supply( Finished and Brand-new and semi-finished Production).



Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks 7m3 4500 kgs Shanghai Port
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks 10m3 6000 kgs Shanghai Port
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks 13m3 7500 kgs Shanghai Port
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 3m3 1200 kgs Shanghai Port
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 6m3 2000 kgs Shanghai Port
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 7m3 2300 kgs Shanghai Port
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5m3 2300 kgs Shanghai Port
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks 3m3 1500 kgs Shanghai Port
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks 8m3 4500 kgs Shanghai Port
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 13m3 6000 kgs Shanghai Port
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 17m3 7500 kgs Shanghai Port
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks 20m3 9000 kgs Shanghai Port
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks 27m3 13000 kgs Shanghai Port
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks 28m3 7000 kgs Shanghai Port
                   
1. Information High frequency change, for reference only.                  
2. Price as formal quotation and technical details and business term                  

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-29



Heater Capacity of destruction of 350 kg/hour


common daily massacre entails 120 pigs. The Condemned item as well as also byproducts from the abattoir for Entry is around 1000 kgs.daily
1 line incinerator for the destruction of damaging clinical waste.

– – – – Heater capacity of damage of 350 kg/hour, calorific well worth of waste will certainly be 13-25 MJ/kg

[3,500 kcal/kg] along with ideal cozy ability 1,225,000 kcal/hr.

– – – – Burner damages ability will definitely be 8.4 tons/day and additionally procedure time will certainly be 24 human assets. / day.

-The temperature degree will certainly regulated in varying flow and also part in oxygen, burning gas is re-burned

from the re-combustion [additional] chamber at a temperature level of minimal 1,100 C throughout 2 secs.

– – – – Control board will certainly be fitted with an useful synoptic sight revealing the operating position of the entire

heater and handled by DCS/PLC system.

– – – – Gas treatment system will absolutely appreciate the EE standard [Directive 2000/76/EC -4/ 12/2000.

– – – – TOC of slag as well as bottom ashes will certainly be less 3 percent of the dry weight.

– – – – Deal will certainly be completely free of visible smoke.

– – – – Heater will certainly be made as a Packaged system, having electrical link pre-wired and continue pipelines

set up.

– – – – Incinerator will have automated de-ashing system with up direction.

– – – – Burner will surely have flue gas treatment system all-inclusive [emergency situation by-pass heap, gas cooling ,

2 activators as well as also particulates filtering method ] as well as assurance of releases from burner.

– – – – Training of AKU workers at website.

– – – – website could be assessed as well as likewise have a peek at present ATI maker, capability 150 kg/hr. In 1 day therapy.

– – – – Web site could be reviewed as well as likewise take a look at existing ATI manufacturer, capability 150 kg/hr. in 1 day treatment.

– – – – Existing facilities space is conveniently available in basement, 100′ ′ Size x 30 ′ large x 20 ′ Altitude for 2nd Incinerator.

– – – – Existing smokeshaft size is 12 meter, and also size is 24″ ″ dia.


Technical Design of Health Care Risk Waste Incinerator


Basic Info.

Model NO.:the price of animal crematory
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and suppliers of medical incinerator, supply and installation medical air in riyadh, supply of incinerator from china, swine incinerator dealers, syc -wwe 100, syc 20 clover medical, other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator with Ease of destruction in weight: 60 Kg/h.


Capacity of jealousy in weight: 60 Kg/h.

it ought to be in a position to operate less than 10 hours/day

This incinerator needs to be able to destruct all combustible wastes generated by hospitals, private clinics, laboratories, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator should prevent the discharge of black smoke and fine dust, (Smokeless) throughout the loadings.

it ought to be able to decrease the volume of wastes from 98%.

it ought to be in a position to hold emission at the next burn with gas residence of less than 2 seconds.

The incineration must be wholly free of visible smoke as well as offensive odours.

The reduced volt electricity (L.C.P) of this waste will be 3,500 kcal/kg

The Temperatures of combustion: Minimum will be 850oC and max 1400oC

Post combustion: >1100oC.

The Inner diameter of the Chimney: Ø 400 and its own height: 8 m

The Loudness of the combustion room: 1.200 L

The Dimension of the door for loading in cm: 70×70.

Burner surgery ought to be Automatic On/Off

Gas: diesel

The supplier must supply necessary information for the top of  the installment

This incinerator with”PYROLYTIC” combustion should contain:

A combustion chamber of waste:

* Perfectly tight door for the manual loading of waste.  The loading must be Manual, Batch Load 

* A burner of lighting which the usage is limited to the ignition of waste.

* Frontage of loading door seals ended up on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.

* The insulation of the combustion chamber ought to be composed of refractory bricks, so using a high content of aluminum and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.

* Composition of the refractory;

Refractory concrete:

. Nature: 42 percent of Al203

Insulate in panels that are fibrous:

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, together with fuel, standard mono-bloc casting directing stirring flame, lighting and security of digital ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 


Containerised Biohazard Incinerator

BIOHAZARD DISPOSAL: CONTAINER

GENERAL INCINERATOR, IDEAL FOR INCINERATION OF VARIOUS TYPES OF WASTE, FULLY CONTAINERISED IN A 20 FT CONTAINER, TO INCLUDE BUILT-IN FUEL TANK AND GENERATOR.

mobile Incinerator

mobile Incinerator

TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME (M3); 0.54 m3. SUGGESTED BATCH SIZE: 60 KG, BURN RATE: 69 KG PER HOUR, AVERAGE FUEL CONSUMPTION 13 KG PER HOUR, OPERATIONAL TEMPERATURE: 950-1320 CELSIUS, GAS RETENTION IN SECONDARY CHAMBER 0.5 SECS, WITH TEMP. MONITORING , AVERAGE ASH RESIDUE: 3%, THERMOSTATIC DEVICE: YES,