china animal cremation


The panel shall comprise of a compartment for the connection of power and control cables. Passage for power cables and

control cables shall be made by the bottom part of the switchboard.

 

 

 

 

The drawer shall be locked in the isolated position by padlocks.

 

1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by

custom authority to burn different kinds of drugs. All need equipment must be provided.

2.Warrantee:  booth systems must be provided with 3 years warrantee from the date of acceptance. All needed spare

parts, preventative maintenance repair and corrective maintenance must be included in the cost and provided to the

customer.

3.All needed electric and water connections must be provided.

4.Both systems must be of high quality and must be environmental friendly.

5.The capacity of each system should be up to 100 kg/hr.

6.The system must have automatic feeding.

7.Each system must consists of two burning  rooms, one primary room for burning the drug and another room for burning

the gases  that emit as a result of primary burning.

8.The oven must be made of steel that is rust resistance and with thickness not less than 6 mm.

9.Each system must be of high efficient in burning different kinds of drugs, and should have 99.9% efficiency for

burning organic materials.

10.Waste products should not exceed 5%.

11.System must have automatic ignition system.

12.System should use diesel (HSD) as fuel and should not consume more than  8 to 10 lt/hr .

13.Each system should be provided with fuel tank  of size adequate to operate the system for one full day.

14.The temperature in the primary room should be 850 C ± 50 C. the system should also be capable to operate up to 1050

C ± 50 C. the system should be capable of continues operation and should be provided with cement layer insulator with

adequate thickness.

15.Oven should be provided with heat insulator to allow easy operation.

16.Gas should remain in the secondary room for not more than 1.5 second.

17.The primary burning room  should have at least 2 burners.

18.The secondary burning room should have one burner.

  1. Each system should have doors for ash, exit for air to the chimney and windows to allow looking inside and for

maintenance.

20.Each system should have filtering system for gas processing with 2 tanks using ordinary water. Each water tank

should have capacity of 1000 lt and should be fixed to the system and provided with water level indicator.

21.Each system should have special technology for separating waist products and humidity after gas processing.

22.Each system should have cooling capability after operation.

23.Each system m should be provided with exhaust pipe with 250 mm diameter and 10 m high. The base of the exhaust

system should be 1000 mm. The exhaust pipe should be 6 mm and should be provide with heat insulator.  The exhaust

system should be provided with pressure indicator. It should also provide with ladder and Lightning Arrestor.

24.Electric power: should be 220 volt, 3 phase, 60 Hz, and the motor should not be less than 15 HP.

25.Each system should be provided with control panel and indicators and needed safety equipment and alarm systems. The

control panel should show at least temperature in both the primary and secondary rooms and injectors of the filters and

load.

26.Each system should be provided with alarm system for any breakdown or defect of any component of the system.

27.The following personal protective tools must be provide:

a.Heat resistant garments for 20 persons.

 


Incinerator for hospital waste management

Incinerator for hospital waste management with the following features:

• In high temperatures (pyrolytic incinerator two chambers with temperatures ranging from 950 º C to 1320 º C;

• Ability to destruction of 400 to 600kg per hour;

• Capable of destroying microorganisms;

• Drain ash;

• Drain needle and glass crusher;

• Porch with tap water for hand washing and decontamination;

• Observe the issue of environmental quality standards, emissions fluent and regulation on the issue of waste;install large incinerator to one of the biggest veterinary hospital in KSA so if you will support us with one unit (large incinerator) and environmental with onsite training , the capacity for the unit is 2000 Kg for cattle , horses and farm animals also suitable to all animal waste types , we need it diesel fired . OES-Industrial MultiWaste Incinerator System (Solid/Liquid)

Scope of the Work:
Design, installation and commissioning of multi industrial waste incinerator.
Capacity: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with dual chamber system)
1st chamber-870 Deg.C – 900 Deg.C
2nd chamber-1000 deg.C – 1200 Deg.C

Sources Of The Wastes
The following types of wastes can be treated by using incinerator.
a). bio medical waste/pharmaceutical waste
b). solid chemical waste/textile industries waste
c). liquid chemical waste
d). dyes and intermediate waste
e). organic chemical waste
f). liquid ink waste/acidic residue
g). insecticides/herbicides/pesticides
h). fungicide waste
i). ethanolamine
j). amino ethanol
k). mono ethanolamine
l). ETA,MEA waste
m). wastes after treatment of chemicals in etp plant.
n). mixed liquor waste water
o). alcoholic waste.
p). agricultural liquid chemical waste.
q). sludge mix liquid
r). slurry/adhesive/grease/powder coating wastes.
s). semi solid liquid chemical waste
t). bulk dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass beads
w). used tires.
x). used cotton rags
y). contaminated plastics/resin wastes.
Scope of Work:
Incinerate all types of liquid/solid hazardous/chemical/non hazardous wastes avaliable in the industries with proper scrubbing system with standard emission rates.
The dual stage incinerator helps to burn the waste in two stages , first at a medium temperature of 870- 900 Deg C and the second stage at 1200 deg C
Producing ash and Gaseous fumes which are treated with cyclone type wet scrubber and caustic scrubber to produce air with pollutants in the permitted range and Non hazardous ash mainly inorganic salts.

Incinerator utilities
Incinerator should have following criteria:
Metallic seal structure with ceramic insulation to avoid heat  radiation and control radiant temperature
Advanced gas treatment system to avoid emission of toxic gases (scrubbing system).
Low consumption high efficiency compact automatic burning system.
Low running and maintenance costs
Fully automatic and simple to operate control panel
Afterburner Preheat
Dense refractory concrete lining rated at 1600 C
Solid Hearth to allow maximum Burnout
Large Top opening lid for easy loading
Wide door for ash removal
Optional Stainless Steel Casing
Heat recovery option

pet cremation incinerators


The successful bidder shall deliver the incinerator skid in a container. The container will be emptied by CEB and

returned to the successful bidder / or to its shipping agent. A containerized solution is also acceptable.

  • Electrically operated 220 volt ( 60 Cycle – 1 phaze )
  • Able to complete burning material that turns to ashes all the component elements of the carbon or metal in the

incinerator with a closed air environment ,  <98%

  • Incinerator must maintain the high temperature in the combustion chamber to ensure complete combustion of the

waste , but not to the degree that leads to the formation of a cluster similar to those resulting

 

 

2.9  Interfacing with existing Sludge System

 

– Incineration of industrial wastes, including pesticides and PCBs;

 

– Ability to incineration 300-500 kg / hour.

 

– Complete unit with gas washing system.

 

The incinerator will be connected to the existing sludge handling system. The incinerator sludge tank will be filled

with sludge by means of a sludge circulating pump on the existing system. The sludge tank shall be equipped with

control valves that will open and close according to the level in the sludge tank.

 

 

For the DO tank, its filling line will be connected to the nearest DO supply piping. The DO tank shall be equipped with

a control valve for automatic filling of the tank and level switches that will trigger automatic opening / closing.

 

 

2.10       Supervision of Installation, Testing & Commissioning

 

 

The successful bidder shall also supply its rates for the supervision of installation and testing and commissioning of

the incinerator set. The rates shall not include accommodation charges. The following shall be covered under the

supervision of installation, testing and commissioning charges;


Lab incinerator


That the Whole carcass of animals ( cattle, horses,

Incinerators must be provided in the fuel tank (diesel )
Action ( Quick Start EP – i)
? The minimum capacity of the animal carcass incinerator
The devastation of 1000 lb / hour.

? Clean the incinerator ought to be simple tools,
? Must be a two-chamber incinerators, secondary and primary
? Must have fuel with automatic controller and malfunction
Detection system.
As standard equipment a particular truck


Installation on High-Temperature Pyrolysis Burning Medical a


Basic Info.

Model NO.:laboratory incinerators and medical / hospital in
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd.. Is a top waste incinerator maker in China. We’re local producer and among the greatest exporter of China. Pyrolytic incinerator waste incinerator plant, waste incinerator project in vietnam 2012, waste incinerator refractor, waste incinerator earnings, waste incinerator suppliers, waste incinerators, gear technical is primary waste treatment each one of the planet, for Medical Waste, Animal Incineration, Pet cremation and other good wste. The potential from 10kgs/Hr. To 500kgs/Hr. , up to 6ton per day. Currently we provide different show for local client requirements and design updated incinerator with our top technology. The updated design feature of our assortment of incinerators create them among the most cost effective in the world.

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

medical waste incinerators


All labels with text shall be in English.

 

 

 

 

Anti-Condensation Heaters

 

 

 

 

The Panel shall be provided with a thermostat controlled anti-condensation heater 240 V, 50 Hz.

 

 

 

 

Earthing System

 

All normal non-current carrying metal parts of the panel and associated components shall be bonded to a common copper

earthbar running the entire length inside the switchboard.

 

The earthbar shall be located in the lower part of the frame work and provided with two termination points for

connection to the main earthing grid.

 

 

 

2.5      Ignition Oil Supply

 

 

MEDICAL WASTE INCINERATOR INTALI8ATION

Design, Supply, install, test and commission medical waste

Incinerator as per the attached specification. The price shall

include all accessories including the civil work and spare part

list to make the system complete.

incinerator burning capacity-250kg/hr                                                  NO       1

 

 

 

 

 

 

 

 

Jimma University Referal Hospital

Incinerator

Medical Waste Incinerator

Purpose

For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance

with EU standard on emission requirement

Waste from health care activities

Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected

patients, waste potentially being infected by pathogenic agents.

Pathological waste, human fragments, bold, fetus, all body fluids, human tissues.

Sculpts, needles, infusion sets, blades, glass

Pharmaceutical waste.

Chemical waste laboratory reagents, disinfectants

Expired drugs.

Low radiation radioactive element.

Medical waste incinerator: – Ecological Requirement

-No odor

-No fume

-Definitive treatment of waste

Medical waste incinerator: – Manufacturing Standards

-UL, CE, ASME, ISA EURO emission standard

1.Medical waste incinerator

Construction- CS plate shells, FB reinforcement, caste refractory linings,

insulation and    14 gage aluminum jacket.

Type of fuel- Oil fired (Diesel)

Burning Capacity- 250kg/hr and moisture up to 80%

Duration-8-16/Continuous

Average fuel consumption- Very little as much as possible

Control Type- PLC based operation

Operating Temperature- Primary chamber 800c± 50

– Secondary Chamber 1050c ± 50

Size of incinerator – Not more than 15mx7.20m

Chimney – Q630x25meter height and 7mm thick CS.

Combustion efficiency – 99%

Mode of waste handling – Semi- Automatic via ram loader.

Mode of ash handling – Semi- automatic via grate and ash trolley.

Pollution control equipment- Dry settlement zone

Doors – 1- waste charging door in primary chamber

1-Clinker door in primary chamber

1-Ash trolley access door in primary chamber

1-Clean out door in secondary chamber

Burner -2- ignition burner in primary chamber

2-after burner in secondary chamber.

Type- package mono block-fully automatic

Type of burner operation- modulation control

Forced draught fan- 1- primary air fan

1-secondary air fan

Fuel storage tank- Capacity-2500liter above grond

– Material -6mm thick mild steel

-2-diesel pump, gate valve, sfety valve, strainer

pipe, pressure gage, check valve, control board

Level indicator. Etc

Refractory/insulation thickness- not less than 225mm

Ram loader capacity-0.75m3

Electrical supply -380v/3ph/50 Hz

Finish and painting type- powder coated

Audio/Visual alarm system- burner lockout, overload fault

Electrical accessories – primary and secondary chamber temperature

Controller /indicator, auto controls, electrical

Control switches, push buttons, relays contavtors

Thermocouples, burner sequence controllers,

Timers, emergency stop and alarms.


Disputing statements concerning incinerator

The letter written by Matt Binder in West Hawaii Today Sept. 26 was a rant that should have been printed on the comic page. His effort at sounding the alarm was obviously to cause panic and therefore support his favorite council candidate.Ten years ago, the proposed incinerator project had a price tag of $120 million. Today, Binder places the price tag at $150 million. That is a matter of concern. The fact remains that we need to dispose of the trash generated on the east side of the island before the Hilo landfill reaches maximum capacity. That predictably will occur in a few years.Mr. Binder expresses concern that we will have to reduce recycling to meet the minimal trash requirement or pay huge fines. Recycling is great but not all recyclable materials can be recycled cost-efficiently so maybe it is not such a bad interim idea. He conjures the idea that dozens of trash hauling trucks will need to be added daily to haul the trash. The fact is, the trucks hauling trash are already on the road doing just that today. Only when we generate more trash will there be a need for more trucks to haul the additional trash.The conclusion Mr. Binder reaches as to the reason for his assumption is, as he puts it: campaign contributions. Then he reveals the secret: Mayor Billy Kenoi aspires to higher office. Oh how fortunate we are to have Mr. Binder reveal to us that the mayor has ambitions and if so, is that wrong? Is it his business?It is obvious that Mr. Binder does not support the incinerator concept in dealing with the east side trash. In stating his assumptions, he exaggerates the doomed outcome but never suggests a reasonable solution. It may be that he draws his conclusions from the hot atmosphere we have been experiencing of late or his desire to support his favorite candidate overrode his ability to comprehend the trash situation.