chemical agents to be utilized:
10% heptyl (unsymmetrical dimethylhydrazine) water solution,
heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration,
10% azotic (nitric) acid water solution,
azotic (nitric) acid vapour with concentration up to 1.1 kg/m3;
2. neutralization method: thermal decomposition;
3. neutralization temperature: +800?C to +1200?C;
4. performance:
? vapour capacity: 70 to 200 m3/h,
? water solution capacity: 50 to 500 l/h;
5. inlet pressure: up to 2 bars;
6. automatic control system;
7. overall dimensions shall allow for mounting the unit on a vehicle chassis.
medical waste incinerators manufacturers General Specifications
6mm plate steel sheel construction
11cm 1400 o C Refractory L iner
Temperature controlled Burners
Secondary combustion Burners
Interlock Switch on Load Doors
Separate Ash Door
One Second secondary Residence @ 1000 o C
400 ° C Silicone Based Paint Finish.
Alloy Temperature Sensor
Factory wired and tested
Capacity-20 kg / hr
Primary Chamber-1607 L
Hearth Area-1:36 sq. m
Secondary Chamber-694 L
Primary Burner (oil)-420,000 btu
Secondary Burner (oil)-900,000 btu
secondary Combustion-1/6 hp
Exhaust Stack-46cm x 6m
Electrical Service-220/50
Weight System-5.700 kg
Dimension “D”-152cm
Load Port Height- 60x 60 cm
Ash Port Height -36 x 36 cm
Author Archives: africa-incinerator
Diesel/LPG/LNG burning vital burning chamber/primary combustion burner
Key burning
Diesel/LPG/LNG burning vital burning chamber/primary burning area
Second burning
Residence time in the second chamber not less than 2 secs
Both essential along with the second temperature levels maintained up until all the waste has in fact been entirely stired up
Chimney
Chimney with a very little height of 4 meters over ground level
Minimum leave velocity of the discharges very little less than 10 metres/second
Temperature level Cautions
Visible and/or distinctive alarm to warn the vehicle driver when the second temperature level drops to listed below the needed temperature level
General
Control box that can be separated as well as mounted on different stand a minimum of 1.5 meters from burner at around 1.6 meter
heightItem 1
Burner style A
Melt Rate 65kg/h minimum
Weight (kg), please show:
Secondary Chamber
Gas Retention Time – – – – 2 Secs
– Fuel – Diesel/LPG/LNG, please show
Power Supply for Control Box – 220V-240V 50Hz solitary phase
Minimum running temperature level 850 ° C, please recommend
One year Spare Components Prepare for total maintainability
10m Tube Pipe, recommend size
I000 Litre Gas Tank + Pipeline System, show quantity
Added smokeshaft expansion, show elevation
Solution guarantee, suggest no of years
Thing 2
Incinerator version C.
Burn Rate 250kg/h minimum
Weight (kg) please showProgram.
2nd Chamber.
Gas Retention Time 2 Secs.
Fuel Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V 50Hz solitary stage
. Minimum running temperature level 920 ° C, please recommend.
One year Spare Elements Bundle for full maintainability.
10m Hose pipe Pipe, indicate size.
I000 Litre Gas Tank + Pipe System, indicate quantity.
Bonus smokeshaft expansion, suggest elevation.
Guarantee, indicate no of years
Warmth Waste Incinerator
Capability at least (4000) kg/day (( Day= 16 Working Humans Resources))
Capability at the very least (4000) kg/day (( Day= 24 Working Hrs))
With the following qualities:
* Automatic feeder as initial part of the unit.
* Automatic ash/ leftovers removal as preliminary part of the device.
* Water Injection System to manage the temperature > >
* Flue gas filtering system abiding by EU.
HTW Incinerator design D.
Burn Rate – – – – 150kg/hour minimum. Weight( kg), please indicate:.
Secondary Chamber.
Gas Retention Time 2 Seconds.
Gas Diesel/LPG/LNG, please program.
Power Supply for Control Box 220V-240V, solitary stage 50-60Hz.
Minimum running temperature level 1200 ° C, please program
One year Spare Components Prepare for full maintainability
10m Tube Pipe, show size.
1000 Litre Gas Storage Tank + Pipeline System, suggest quantity.
Bonus chimney extension, suggest height.
Mobile Burner
Item 5.
Mobile Heater version E
Melt Cost 50kg/h minimum
Weight (kg), please program:
Second Chamber
Gas Retention Time – – – – 2 Seconds –
– Gas – Diesel/LPG/LNG, please suggest
Power Supply for Control Box – 220V-240V 50Hz solitary stage
Minimum running temperature degree 850 ° C, please suggest
One year Spare Elements Package for complete maintainability.
Mobile Incinerator
Point 6.
Mobile Incinerator variation F
Melt Rate 100kg/h minimum
Weight (kg), please indicate:
Second Chamber
Gas Retention Time – – – – 2 Secs
– Fuel – Diesel/LPG/LNG, please suggest
Power Supply for – Control Box – 220V-240V 50Hz solitary phase
Minimum running temperature level 850 ° C, please suggest
One year Spare Components Bundle for full maintainability
10m Pipeline Pipe, suggest size
1000 Litre Gas Container + Pipe System, show amount
Additional smokeshaft expansion, show elevation
Service warranty, indicate no of years.
Warmth Waste Mobile Incinerator.
Product 7.
HTW Mobile Heater version G.
Burn Cost 100kg/h minimum.
Weight (kg), please suggest:.
Second Chamber.
Gas Retention Time – – – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – – – – 220V-240V 50Hz solitary stage
Minimum running temperature level 1200 ° C, please suggest.
Key burning.
Diesel/LPG/LNG burning primary burning chamber/primary combustion area.
2nd burning.
Residence time in the second chamber not much less than 2 seconds.
Both primary and the additional temperature levels protected up until all the waste has been totally ignited.
Smokeshaft.
Smokeshaft with a marginal altitude of 4 meters over ground level.
Minimum leave rate of the emissions not less than 10 metres/second.
Temperature level Cautions.
Audible and/or noticeable alarm to encourage the driver when the additional temperature goes down to listed below the called for temperature level.
General.
Control box that can be separated as well as mounted on separate stand at least 1.5 meters from burner at about 1.6 meter
altitude.
Assurance, show no of years
Weight (kg) please show:.
Service warranty, indicate no of years
Warmth Waste Burner
Ability at the very least (4000) kg/day (( Day= 16 Functioning Hrs))
Ability at the very least (4000) kg/day (( Day= 24 Working Hrs))
With the complying with qualities:
* Automatic feeder as original component of the device.
* Automatic ash/ leftovers elimination as preliminary element of the system.
* Water Injection System to control the temperature level > >
* Flue gas filtering system following by EU.
* Consistent discharge monitoring and also recording system.
elevation.
Guarantee, show no of years
china medical incinerator
the following containerized incinerators. (Kitchen and accommodation and grey water and black water plant removing waste) we need incinerator is each function separate are all in one incinerator we need informed. Plant we installing for our accommodation barge used in an offshore marine construction project. 200 People would be accommodated onboard.
WASTE INCINERATORS RECOMMENDATIONS
china medical incinerator Capability
?Incinerate minimum 80kg/hr X 12 hrs per day
?Disposal of both non-hazardous and hazardous waste streams (per waste inventory)
?Mobile Unit (Skid mounted preference with lifting points)
Design/Specifications
?Incinerators must have a secondary combustion chamber with a minimum temperature range of 900c
?Liquid waste streams shall be incinerated by an appropriate liquid injection system
?The incinerators will be installed with visual alarms to alert operations of low temperature in the secondary chamber
Operating Environment and Ambient Conditions
The Incinerators package shall be designed to operate under the following conditions:
?Average Daily Max/Min June Temperature, 21-39°C
?Average Daily Max/Min January Temperature, 2-12°C.
Medical waste incinerator,
approx. 0.4 cubic metres,
diesel fuel / mains power operated,
thermostatic temperature control,
programmable cycle
Incinerator
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize in this gear? A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t indicate any waste material. The animal/pet combustion rate around 2/3 of ordinary capacity.
Clover incinerator utilize time daily to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time incinerator furnace manufacturer, incinerator hospital price, incinerator in hospital, incinerator maker in shanghai, incinerator manufacturers in usa, and time for feeding waste. Actual combustion time daily is about 16 hours. The life of incinerator between 5-10 year according to utilize.
Ordinarily, we proposition small laboratory, small clinic use capacity under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output capacity around 2kgs per individuals per day. If there are 200 sickbed at the clinic, that's imply you need 1 incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the performance time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs each hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Meeting and Testing A: We supply all files and incinerators simple to setup and functionality. Customer can send individuals visit our factory to find out operation and installation. Generally, we don’t send engineer to local site if not ask. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi degree. PLC mode according to model and order.
One person can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know risk of medical waste to safeguard worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
durable and highly efficient incinerators with various capacities for hospital/medical waste, cremation and other solid waste treatments
Single and Dual Chamber Medical Incinerator.durable and highly efficient incinerators with various capacities for hospital/medical waste, cremation and other solid waste treatments.
Chamber Double
Burning Rate 10 kg per hour (for two incinerators)
Burning Rate 20 kg per hour (for three incinerators)
Loading Method Manual
No of Burners Single for 10 kg/hour and Double for 20 kg per hour
Fuel Diesel and Natural Gas
Warm Up Time Not more than 20 minutes
Temperature controller Digital
Power Supply Single Phase 220V
Chimney Height 20 feet from ground level
· 50kg per hour
· Option for medical waste.
Type
Single Chambered Cylindrical
Feed Material
Papers, Cartons wastes
Capacity
1000 Kg/Day
Burning Capacity
125 Kg/hr
Design Standards
Generally confirming to IS Standards
Type of burning operation
Zero Fuel System
Combustion Chamber
Type
Cylindrical
Dimension
1.25 m Dia (Approx) x 1.2 m Height (Approx)
Temperature
400 – 600 °C
MOC
Chrome Alloy Steel, inside lining with fire bricks/Ceramic Clay
Outer Lining
Thermal Proof Lining
STACK
Type
Self Supported
MOC
MS
Accessories
Port Hole and Ladder for emission testing with complete online scrubbing system, thermostat
The units will be used for our client camps in the field. These Camps range in manning size from 20 – 200 people. Each site has a medical clinic, a very small use for medical but will need it.
medical incinerator 20kg
We are looking for small incinerators with filter (with least minimum pollution) for burning/combusting 5kg/hr,
10kg/hr, 15 kg/hr, 20kg/hr, 25kg/hr to 50kg/hr and 300kg/hr of SOLID ORGANIC DRY AND WET NON-HAZARDUOUS of any kind
(including hospital wastes) per day or per hour. Should it be with no smoke, no fumes, no odour (smell), no dust, no
emission of solid particles and with least minimum pollution (within national and international standards). Must be
environmentally healthy and acceptable with international standards. Should not be with water scrubbers. Ash contents
after burning should be 3-4%.
Please incorporate this alarm as it is a requirement.
- In addition to the above the following instruments may also be required.
A carbon monoxide and/or oxygen meter/recorder
A smoke density meter/recorder
A gas flow meter/recorder
A solid particulate meter/recorder
Any other instrument or measurement that may be considered necessary–none
8 Location / Siting 1. Must be sited in accordance with the relevant local municipal authority
planning scheme, the topography of the area and be compatible with premises in the neighborhood,
- Must be housed in a suitably ventilated room.
9 Emission Limits 1. Combustion efficiency:
Combustion efficiency (CE) shall be at least 99.00%
The Combustion efficiency is computed as follows;
C.E= % CO2 x 100
% CO2 + CO
- We are interested to work on Medical Incinerators in our country and looking for a company offering good
quality with reasonable prices, Initially we are interested for incinerator with a burning rate of 30 – 50 Kg/hour.The
temperature of the primary chamber shall be 800 ± 50o C
- The secondary chamber gas residence time shall be at least 1 (one) second at 1050 ± 50o C, with 3% Oxygen in
the stack gas.
4 Opacity of the smoke must not exceed 20% Viewed from 50 meters with naked eyes
- All the emission to the air other than steam or water vapour must be odourless and free from mist, fume and
droplets.
Minimum Setup Incinerator
Product Description
From year 2010, we negotiated with upgraded technologies from Europe and America producers and establish alliance relationship in the territory of China market. Unfortunately, competition in other countries market, state discrimination and worries of intellectual property medical waste incinerator home, medical waste incinerator in china, medical waste incinerator in georgia, medical waste incinerator italy, rights cause failure eventually. Presently, we investment more effort, funding and technology development in our own brand, we are to be one of the most significant incineration equipment in the world. Nanjing Clover Medical Technology Co., Ltd.
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi gas. As different circumscription, incinerator can be termed many words
As below:
Treatment ability: Small scale incinerator, large scale incinerator and incineration pant.
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators
Incinerator gas: Gas incinerator, oil incinerator
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator
Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Tel: +86-25-8461 0201
Fax: +86-25-8461 0406
Item | Customer Request | Example |
Application Scope | |
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc |
What kind of waste? | ____, _____% ____, _____% ____, _____% |
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent if for animal/pet, indicate animal size like: cat, dog, cattle, etc |
Quantity Request | 01.02.03^…unit |
|
Budget | $US Dollar. |
|
Operating Time | The staff work Hours per day. Our incinerator can work up to around 18 hours per day. |
|
Realization Date of project | In ___ year | |
Waste Output Capacity per Day? | |
1000kgs Per Day^ |
Request waste burn rate | Capacity: 100kgs Per hour^ | |
Request waste feed capacity | Capacity: 100kgs per feed^ | |
Whether Natural Gas Supply Local? | Yes or No. | |
Local Power | If 380V and 220V valid? | |
Product Installation Destination | |
Country or City name |
DestinationSeaport name? | To check sea freight charge. |
|
Customer | End-Customer, Agent, Government. |
|
Method of contract | Tender or Negotiation | |
Date of Tender limit | ||
How did you know our company? | ||
Other request or information | |
50 Kgs Per Hour Incinerator
Basic Info.
Additional Info.
Product Description
Items | Specification | |||
YDC Model | YD-10C / YD-20C / YD-30C / YD-50C | |||
Main Product List | Primary Combustion Chamber | |||
Secondary Combustion Chamber | ||||
Mix Combustion Chamber | ||||
Smoke Filter Chamber | ||||
Incinerator Common Control Case | ||||
Stainless Steel Chimney | ||||
Italy oil/gas burner: 02 units | ||||
Oil Tank (if oil fuel) |
Nanjing Clover Medical Technology Co., Ltd., Neighborhood in Nanjing city, China.