Medical Waste Burner HICLOVER TS10 PLC 10kgs per human resources


medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour

Items/Model

TS10( PLC)

Image

Melt Price

Frequent 10 kg/hour

Feed Capability

Requirement 20kg/feeding

Control Mode

Programmable Reasoning Controller( PLC) Tool

Combustion Chamber

100L

Indoor Dimensions

50x50x40cm

2nd Chamber

50L

Smoke Filter Chamber

Yes

Feed Setting

Handbook

Voltage

220V

Electricity

0.5 Kw

Oil Usage (kg/hour)

standard 8.4 kg/hour

Gas Usage (m3/hour)

standard 10.1 m3/hour

Temperature degree Display

Yes

Temperature Defense

Yes

Oil Storage Container

100L

Feed Door

30x30cm

Smokeshaft

5 Meter

Smokeshaft Kind

Stainless Steel

1st.

Gross Weight

1500kg

External Dimensions

140x90x120cm

2020-06-30

Exterior Measurements

140x90x120cm


























hazardous waste disposal companies
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-30


SOLID WASTE INCINERATOR

Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal.

Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating. bio medical waste treatment plant ( Incineration )with panel.

SOLID WASTE INCINERATOR    Feeding Capacity:    200 to 220 Kg.
Burn Rate *    60 Kg / hr
Ingredients to be burned    Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc.
Chambers *    Dual Chamber.
1: Primary Controlled Air
2: Secondary Excess Air
Temperature Monitoring    Required
Temperature Control to Primary & Secondary Chambers    Required
System Status & Alarms    Required for all necessary parameters.
Fittings & Accessories    Complete Package is required ( Including Nozzles & Flanges etc.)
Installation Requirements.    As low as possible . Almost Plug & Play type.
Dimensional Sketch, Operation & Installation Manuals.    Required
Off – Gas System    Required
Heat Insulation    Required for indoor installation
Delivery    Karachi Sea Port – Pakistan

The details of Components of incinerator is as follows:
Component Name        Features                 Range.
Primary Chamber    Temperature Required*    800 – 1000 deg C.
Heating Source    Natural Gas

Secondary Chamber    Temperature *    1100 – 1300 deg. C
Heating Source    Natural Gas + Propane or Fuel Oil as an additional source
Off – Gas Residence Time     2 Seconds.
Refractory Material    Material *    Alumina ( 56 – 80 % Pure )
Lining *    SS 316L
Life Span *    10 – 15 years.
Rating Temperature    1600 – 1800 deg. C
Media    Slightly acidic
Insulation    Material    Ceramic Fiber
Thickness    25 “ minimum
Feeding & Ash Removing     System    Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Spares    Required for 5 Years trouble free operation

Sudan Medical waste Therapy Strategy



•    A burn rate of 25 – 30kg/hr.
•    Consists of two chambers to ensure significant reduction of emissions and be capable of temperatures in the range of 800-1000˚c.
•    Incinerator must be of a low maintenance design, be diesel fuelled and need no more than 15 amp 220-250 V power. KW consumption per hour should be stated.
(1)  What  are  main  differences  between  medical  incinerators:    YD-10C  and  TS10(PLC)?
(2)  After  combustion,  the  medical  waste  becomes  smoke?  Without  smell?  No  pollution?
(3)  What  should  we  do  to  release  the  smoke?    Prepare  a  pipe  to  direct  the  smoke  to  factory  outside?
(4)  Any  operation  guide  for  reference,  we  worry  that  it’s  difficult  to  operate?
•    The incinerator should also be able to run off a generator.
•    The incinerator should have option of tank and should use no more than 12L of diesel fuel per hour to burn 25- 30kg of waste.options for medical waste incineration for Kabul, Afghanistan
•    Design must be such to minimize risk to operators and have a simple start sequence to minimize operator training and skills
•    Solid waste reductions in the range of 90 – 97% should be routinely achieved.a central thermal treatment station in the city of Khartoum (9 million inhabitants) we started with two units of autoclave that treat up to 18 tons a day so far, and looking forward to add an incineration plant/s to serve for medical, pharmaceutical, and hazardous waste.



Waste Management Incinerator Technology


Basic Info.

Model NO.:incinerator manufacturers
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may use in this gear?  A: This gear to medical waste, pet creature, Municipal waste, reside squander. Prohibit any volatile and radiation substance, liquid gas and waste waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001.  The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time plus time for feeding squander. Actual combustion time per day is about 16 hours. The life of incinerator involving 5-10 year based on use. 

Ordinarily, we proposition little laboratory, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output around 2kgs per individuals every day. If there are 200 sickbed in the hospital, that's imply you need 1 incinerator capability around 400kgs every day, change to capacity per hour is around 30-40 kgs per hour. According the operation time every day, waste material, funding, growth, etc, you may use capacity from 30-50 kgs per hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Meeting and Testing  A: We provide all files and incinerators easy to installation and operation. Client can send individuals come to our factory to learn operation and installation. Generally, We do not send engineer to local site or even ask. The dispatch price is extra based on order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi degree.  The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control mode is common control instance. PLC mode based on order and model. 

Q: Operation and maintenance costs  A: Operation price based on fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD annually maintenance according version, use situation. 

One person can service 02 device incinerators. Hospital incinerator manufacturers, incinerator burners, incinerator diesel burn, incinerator manufacturer china, incinerator medical waste maker, incinerator providers, The staff must have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know risk of medical waste to safeguard worker self with necessary security element. 

Q: The Residency period in combustion chamber  A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Top Feeding Door Solid Waste Incinerators HICLOVER


HICLOVER Top Feeding Door Waste Incinerators

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke



parts of an incinerator
physical method of disposing hazardous chemical waste
portable incinerators types
proper ways of waste disposal in the community
questionnaire to ask about incinerators for collection of data

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-08-07


50-100-150-200 Kgs per Hr Solid Waste Incinerator for sale



Waste Incinerator Design TS150 PLC, Testimonial

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate

Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people

— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:

Items/Model


TS150( PLC)

Photo

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*( 50/100/200kgs/ hr optional)

Feed Capability

Standard 750kg/feeding

Control Establishing

PLC( Programmable Logic Controller Heater)

Text Steel

8mm thickness

Chamber Product

High Alumina Fire Block Wall, 1750 ℃ Rate

Paint for outdoors face

800 ° C Rate

Burning Chamber

1570L

Internal Dimensions

150x100x105cm

2nd Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Consumption (kg/hour)

Common 20.4-28.0( D.O)

Gas Intake (m3/hour)

***

Temperature Level Screen

Digital Program

Temperature Level Safety

Yes

Oil Container

300L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Type

Stainless-steel

1st.

Gross Weight

8500kg

Outside Dimensions

300x160x280cm( without smokeshaft)

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without smokeshaft)




 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



family pet dog incinerator up for sale



1. Capability of damage in weight: 60 Kg/h.
2. It should be able to run very little less than 10 hours/day
3. This burner needs to have the ability to destroy all combustible wastes created by healthcare facilities, unique centers, research laboratories, institutes, and so forth.
4. Style Requirements: Kinds A, B, C, D, as well as E of clinical waste
5.” PYROLYTIC” burning, by taking care of the gasification of waste.
6. The burner needs to remain clear of the release of black smoke as well as likewise fantastic dust, throughout the loadings.
7. It must have the capacity to minimize the volume of wastes by 98%.
8. It should certainly be able to hold discharge in the 2nd shed with gas house of not much less than 2 secs.
9. The incineration must be entirely without noticeable smoke in addition to upseting odours.
The minimized calorific power (L.C.P) of this waste will be 3,500 kcal/kg
? The Temperature levels of burning: Minimum will be 850oC as well as likewise max 1400oC
?
The Quantity of the burning chamber: 1.200 L.
13. The Measurement of the door for filling in cm: 70 × 70.
14. Heater procedure need to be Automatic On/Off.
15. Fuel: diesel.
16. The company needs to supply needed details for the best of the installment.
This heater with “PYROLYTIC” burning need to have:.
17. A burning chamber of waste:.
* Totally restricted door for the hands-on loading of waste. The loading must be Manual, Set Lots.
* A heater of lighting which the usage is restricted to the ignition of waste.
* Frontage of loading with door seals boosted on joints, wheel of screw plug, versatile joint, as well as also loading protecting out of refractory.



low-cost medical waste incinerator


Stack:
Type:  Wire Supported
MOC:  Mild Steel of ISstd
Height :3 Meters or more
• PROCESS AT LEAST 1 METRIC TON OF WASTE PER DAY
• OPERABLE BY 1 PERSON, WITH NO TRAINING REQUIRED
• REGULAR MAINTENANCE CAN BE COMPLETED BY 1 PERSON WITH LIMITED TRAINING
• REGULAR MAINTENANCE SHOULD NOT EXCEED 1-HOUR PER DAY
• COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
• ABILITY TO INCINERATE WASTE PETROLEUM, OILS, AND LUBRICANTS
• TEMPRATURES DURING THE COMBUTION PROCESS MUST EXCEED 1,500 °F FOR AT LEAST 1-HOUR
• CAN BE TRANSPORTED TO AND FROM DEPLOYMENT LOCATION IN A 20-FOOT OR SMALLER SHIPPING ISO CONTAINER
• CAPABLE OF 24 HOURS OF CONTINUOUS USE
• AUTOMATIC LOADING SYSTEM
• AUTOMATED ASH REMOVAL SYSTEM
• GAS SCRUBBING SYSTEM
• 95% REDUCTION OF SOLID WASTE
• OPERABLE WITH DIESEL, JP8, OR FUEL OIL
• CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
• ABLE TO INCINERATE COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, AND

WOOD PALLETS.
• NO PRE-TREATMENT OF WASTE REQUIRED
• VENDOR REPAIR OFFERED AT POINT OF SHIPMENT
• FIVE (5) YEAR COMPONENT WARRANTY FROM DATE OF ACCEPTANCE
We are an aerosol manufacturing company.. Our products includes Deodorants, Anti perspirant deodorants ,air freshners,

Insect killers etc..