Clover Medical Medical West Incinerator


Basic Info.

Model NO.:china animal incinerator manufacturer
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste can utilize within this equipment?  A: This equipment for medical waste, pet creature, Municipal waste, dwell waste. Prohibit any explosive and radiation substance, liquid gas and waste waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001.  The animal/pet combustion rate around 2/3 of ordinary power. 

Clover incinerator utilize time per day up to 24 hours. Between each feed/combustion time, you will find about 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time daily is around 16 hours. The lifetime of incinerator involving 5-10 year based on usage. 

Ordinarily, we proposal little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed at the hospital, that's mean you need one incinerator capability around 400kgs daily, change to power per hour is around 30-40 kgs per hour. Incinerators 150 kg per hour, incinerators 300 kg per hour, big incinerator, medical incinerator design, health incinerator Italy, According the performance time per day, waste material, budget, development, etc, you can use ability from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing  A: We provide all files and incinerators simple to setup and operation. Client can send people visit our factory to find out operation and installation. Generally, we don’t send engineer to neighborhood site if not request. The dispatch cost is extra based on order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi degree.  The next combustion chamber: 1000-1200 centi degree.  PLC mode based on order and model. 

Q: Operation and maintenance costs  A: Operation cost based on fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One individual can service 02 device incinerators. The staff should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, and understand risk of medical waste to safeguard worker self with essential protection element. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Pet Animal Cremation Machine

We have Family pets, after they are dead, the best way for pet dog, cat is cremation.

The farm animal, dead chicken, cow, best way is cremation for environmental protection.

We supply incinerator for pet animal cremation, from small pets dog, cat to big animal like pig, cow.

animal crematory

Planning application submitted for massive Deeside incinerator plant.

incinerator plant

The American-owned firm behind the Parc Adfer waste treatment facility has submitted its planning application to Flintshire County Council.

Energy-from-waste specialist Wheelabrator has submitted plans for its proposed 200,000 tonnes per year capacity incineration plant on the edge of Deeside industrial estate.

The company was named as the preferred bidder for a 25 year contract to treat household waste on behalf of North Wales Residual Waste Treatment Project (NWRWTP) – the five council partnership which includes Flintshire, Isle of Anglesey, Conwy, Denbighshire and Gwynedd.

The firm hopes that planning consent could be granted during the first half of 2015, allowing construction work to commence late in the year.

If successful Wheelabrator expect the facility to be operational by 2018, the site will the then supply waste heat through steam pipes to nearby industrial or commercial users, as well as incinerate tonnes of household waste, diverting it from landfill sites.

According to the five councils, the facility will help them towards meeting the Welsh Government target to recycle 70% of waste by 2025.

30 kg per hour-incinerator


Secondary combustion chamber shall be either the rotary- or stationary-hearth (or kiln) type incinerator designed to

 

oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be fully automatic

Diesel incinerator of 25Kg / h

 

 

Box

Box dimensions of the incinerator.

 

Approx Width: 900 mm

Approx: 1000 mm

Approx height: 1000 mm

 

Dimensions of the chimney

 

Min height: 6000 mm

Diameter: 300 mm

 

Provided with two primary and secondary chambers.

Primary chamber volume: 0.25 m3

Secondary chamber volume: 0.25 m3

 

Made of steel with refractory lining

Door removal of grays

Display draws in both chambers

Temperature probes PTC type

 

Burners

Thermal Power Max: 5100 Kcal / h, 59 kW

Min 1700 Kcal / h, 20kw

 

Consumption approx. 2.6 to 5.0 kg / h

Voltage 230V-50Hz

Fan 75W, Rotation 2800 Rpm

Ignition transformer

Ignition means electrodes

Controller burner

Table controller

Thermometer digital camera primary and secondary

Regulating combustion head

Air regulation

Fuel: Diesel


China Arrests 60 For Waste Incinerator Protests

Residents were protesting waste incinerators without proper emission filters.

Residents were protesting waste incinerators without proper emission filters.

Early this week, protests erupted in China over plans to build a waste incinerator in an eastern city where officials didn’t seek public approval before proceeding. The demonstrations have been running for more than two weeks and turned violent on Saturday, with hundreds of police descending on to the streets of Yuhang, close to the eastern tourist city of Hangzhou. Previous to this week, officials repeated in state media that they would seek public support for the incinerator, but recently have made dozens of arrests in Hangzhou, with at least 10 demonstrators and 29 policemen injured.

Waste incinerators without proper emission filters can release the carcinogen dioxin, said Wu Yixiu, head of environmental group Greenpeace’s toxics campaign in East Asia. Several neighbors of the Hangzhou site cited that risk and noted that incinerators in Germany were required to filter out the toxin. Following large protests in March against a proposed paraxylene plant in the city of Maoming, officials said they would not proceed with facilities if public resistance remained high.

China’s fast growing cities produce around 160 million tons of domestic waste each year, according to domestic reports, and the country is planning around 300 such incinerators within the next three years as part of a “Great Leap Forward in garbage incineration”. For years, China witnesses tens of thousands of so-called “mass incidents” which have recently been linked to several environmental issues. In March, Li Keqiang, the prime minister, vowed to “declare war” on pollution and said his country would turn its back on “inefficient and blind development.”

BIOHAZARD DISPOSAL INCINERATOR CONTAINERISED IN A 20 FEET CONTAINER



BIOHAZARD DISPOSAL: CONTAINER

GENERAL INCINERATOR, SUITABLE FOR INCINERATION OF VARIOUS KINDS OF WASTE, ABSOLUTELY CONTAINERISED IN A 20 FT CONTAINER, TO CONSIST OF BUILT-IN FUEL CONTAINER As Well As GENERATOR.

TECHNICAL SPECS: SHEDDING CHAMBER AMOUNT (M3); 0.54 m3. SUGGESTED SET SIZE: 60 KG, BURN COST: 69 KG PER HR, STANDARD GAS USAGE 13 KG PER HR, OPERATIONAL TEMPERATURE: 950-1320 CELSIUS, GAS RETENTION IN SECONDARY CHAMBER 0.5 SECS, WITH TEMPERATURE LEVEL. MONITORING, STANDARD ASH DEPOSIT: 3%, THERMOSTATIC TOOL: YES,
DIMENSIONS: OUTSIDE LENGTH (mm): 1520MM, EXTERNAL SIZE (mm): 920MM, EXTERNAL HEIGHT (mm): 4020 MM
1. Burner for Bio-Medical Waste incineration needed
2. 50 kg/hr
3. 2 chambers have to exist
4. temperature degree of main chamber ought to be 850 levels Celsius
temperature level of added chamber must be 1200 levels Celsius



Incinerator Furnaces for Pet Cremation


Basic Info.

Model NO.:incinerator manufacturers in middle east
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long lifetime of incinerator.  * Free or minimum installation on site.  * High speed, from 10kgs to 500kgs per hour, up to 6ton per day.  * PLC Control Plane. *according to order  New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock. 

Application Scope:  1. 2. Slaughter House &esign incinerator sampah, style of medical waste incinerator, design of little medical waste incinerator, designer medical incinerator, destructor incinerator,  Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

Nanjing Clover Medical Technology Co., Ltd.. Is a top waste incinerator manufacturer in China. We are local manufacturer and among the largest exporter of China. Pyrolytic incinerator gear technical is primary waste treatment each one of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The potential from 10kgs/Hr. To 500kgs/Hr. Up to 6ton per day. Currently we provide different show for local client requirements and design upgraded incinerator with our top technology. The upgraded design feature of our range of incinerators create them among the most cost effective on the planet.

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

chinese incinerator manufacturers

In a simple design with a metal steel drum electric. including:
A cage for receipt of biomedical waste;
A combustion chamber with fireplace with a filter to retain ashes;
A cover;
An air supply;
A turbine  allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories
Supply of incinerator model PDR-18 with:

·        Capacity 100 kg/hr of waste containing up to 85% moisture

?      Two combustion chambers

·        Two fully automatic, oil fired, pressure jet burners

·        Panel board

·         Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
Type: for animals waste
Capacity: 30 kg per hours for a maximum load of 120 kg.
GLP Gas
Voltage: 110V-120V
Semiautomatic control board
Stainless steel chimney, 3.5 meters above the incinerator.
High temperature painting for all the incinerator.
Front door for loading and unloading.
Fuel    Diesel Oil 8/ kerosene
Capacity (m3)    0.57
Ave Capacity    50 kg per hour
Ave time for Burnout     5 hrs
External Dimensions
Length    2000mm
Width    1100mm
Height including flue    3500mm
Door opening
Internal Dimensions
(primary chamber)
Length    1200mm
Width    620mm
Height     660mm
Operation
Min. operating temperature    9500C
Max. operating temperature    13200C
Residency time in second chamber    2.0 seconds
Weight    1850kgs
Ancillaries
Operating and maintenance manuals
Recommended Spare list
300 liter fuel tank
Plant burning rate – 100kg/hr

Fuel – Diesel oil   – 35 sec Redwood

Overall dimensions are as follows:

Width    2261mm

Length  3264mm

Chimney Diameter  –  390mm

Chimney Height      –  8000mm
chinese incinerator manufacturers, We process 8-10 ton waste of sheep carcass and its byproduct per day. We are looking for the equipment: combustion burners(combined fuel supply:natural gas and diesel),control panel and filter system. The diameter of the incinerator is 20 cm. Lower calorific power of the waste is 4KW/KG. Heating power 4000KW