WASTE CATALOGUE AND HAZARDOUS WASTE LIST

1 Incinerator 30 =KG  burn/h and it must have a Scrubber.

2 Incinerator must have Electrical Plastic Shredder for cutting of glass bottle,surange of Medicine.

3 Incinerator must have Electrical Auto Clave or Microwave for Dis Infection  separately with incinerator.
4 Incinerator must have Double Chambers first Chamber must gave 800C temperature and secondary Chamber working 1200C temperature.
5 Incinerator in out place must have a Parameter to show inner temperature of incinerator.
6 Incinerator must work in two systems Electric and fuel describe in which kind of fuel works.
Note we want it works on diesel fuel and electric also.for a small pig slaughterhouse project in Vietnam we are looking for a
solution to destroy safely inedible  and seized animal products.

As the slaughtered pigs are consumed by more than 90% (from hooves to
head, blood, etc) the waste volume is quite small even in
slaughter-points with up to 100 slaughtered pigs per day.

Although the use of meat and bone meal is not prohibited in Vietnam the
small volumes of waste do not seem to justify the installation of a
rendering unit, not even of a batch cooker, so incineration seems to be
the best option.

I would like to receive more technical details e.g. fuel consumption for
incinerating 100/200 kg of animal products per day and also the FOB
price of the unit.The types of waste to be treated are (after EUROPEAN WASTE CATALOGUE AND HAZARDOUS WASTE LIST, 2002):

18 01 01 sharps (except 18 01 03)

18 01 02 body parts and organs including blood bags and blood preserves (except 18 01 03)

18 01 03* wastes whose collection and disposal is subject to special requirements in order to prevent infection

18 01 04 wastes whose collection and disposal is not subject to special requirements in order to prevent infection (for example dressings, plaster casts, linen, disposable clothing, diapers)

18 01 06* chemicals consisting of or containing dangerous substances

18 01 07 chemicals other than those mentioned in 18 01 06

18 01 08* cytotoxic and cytostatic medicines

18 01 09 medicines other than those mentioned in 18 01 08

18 01 10* amalgam waste from dental care

incinerators for Liberia

1) minimum with a burning area (kiln) of at least 2.8 m3   (KG/Hour is not the driving factor)

2) Large – Must reach 1300 degree temperature or higher and approved for medical waste burning and be capable of burning > 4 m3 of materials at one time (the Hurikan 500 incinerator model or equivalent).
– fully EU legislation ABPR 1069/2009 compliant and for efficiency and clean emissions

Construction:
Mild steel welded fabrication consisting of sheet steel and structural section supports and bracings. Articulated trailer supplied in compliance with the country of destination.

Lining:
Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal.

Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating.

Judge blocks Ebola victim’s incinerated belongings from entering Louisiana

BATON ROUGE, La. (WGNO) – A temporary restraining order has been granted blocking the disposal of incinerated waste from the Texas Ebola victim’s personal items at a Louisiana landfill.

The restraining order, signed by Judge Bob Downing Monday afternoon requires the transportation of the waste from a facility in Port Arthur, Texas to stop immediately.

According to a statement from Attorney General Buddy Caldwell’s office the burnt waste could amount to six truckloads. Potentially contaminated items from Thomas Eric Duncan‘s apartment were incinerated Friday in Texas.

The material was slated to be transported to the Lake Charles Chemical Waste Management Inc. facility. On Monday CWM told Veolia Environmental in Port Arthur, Texas, where the wasted is currently, that they will not be accepting the ashes because they do not “want to make an already complicated situation, more complicated.”

Adding that, “medical waste and hazardous waste incinerator ash, which is the residual that results from incineration, is not capable of transmitting infectious disease, including Ebola, and is safe for transport and disposal in a solid waste landfill without any impacts on human health or the environment.”

In a statement issued Friday, Veolia Environmental detailed how they decontaminated all Ebola waste. Read more here.

The Centers for Disease Control and Prevention has said properly burned Ebola materials pose no risk to humans.

Attorney General Buddy Caldwell said, “We certainly share sadness and compassion for those who have lost their lives and loved ones to this terrible virus, but the health and safety of our Louisiana citizens is our top priority.

“Even the CDC and our health care workers seem uncertain as to the effectiveness of purported protocols in dealing with Ebola.  There are too many unknowns at this point, and it is absurd to transport potentially hazardous Ebola waste across state lines. We just can’t afford to take any risks when it comes to this deadly virus.”

The temporary restraining will remain in place until the court order to grant preliminary injunction can be heard on Oct. 22 before Judge Downing.

Medical Waste treatment unit

Medical Waste treatment unit

The medical waste treatment unit shall be environmentally-friendly, and have a capacity of
about 200-300kg per batch , to enable treatment of medical waste generated in a 160-bed
hospital
The equipment should be self-steam generating if
steam is needed for the sterilization process.
The medical waste treatment unit shall be capable of processing the following:
• Bagged waste, in ordinary bags.
• Sharps containers.
• Liquid containers.
• Cardboard containers.
• Metal objects.
• Pathological waste.
The medical waste treatment unit shall be able to
• mix the waste and shred it into small pieces
• sterilize the waste.
• Dehydrate the waste
• Compact the waste to reduce its volume
Unloading of treated waste shall be automatic, with further shredding facility
All operating features shall be safe, automated
1.  The entire cycle shall be computerized with all essential operating parameters locked in and
password protected.
2.  There shall be a documentation feature of the treatment cycle,
The unit shall have a manual mode of operation in case of failure of the automatic features
The following parameters shall be displayed:
1.  Power on
2.  sterilization indicator light
3.  auto/manual switch
4.  open door warning light
5.  steam pressure
6.  cycle chart recorder

manufacturing facility established Diesel Fired Heater



Estimados, agradecería una cotización por los hornos crematorios para mascotas modelo YD-30/ YD-50. Mobile Diesel Fired Burner layout
provided with the adhering to requirements:
complete with constant air flow fans for removal,
producing center established inside one 20ft ISO container overall with lighting, air flow follower, fire security, 3 access to doors, and also a 1200 litre fuel tank full with a piping.
Totally containerised mobile waste monitoring solution for professional, pet dog, as well as hazardous waste applications.
Establish in Container (ISO): 20″″.
or its neighborhood equivalent model approach to create a burner plant with 3 devices of heaters at the capacity of 500kg per human resources each.
Together with various other centers like procedure office, store, area to neat waste containers and additionally 3-4 worker living quarters.
Necesito saber.
1. ficha tecnida.
2. guía mecanica.
3. elevaciones.
Los quemadores child Ecologicos.
Del YD 50 and also. YD 100 Long Life pet dog crematory.
in Diesel ……… …. Me interesa este producto Long Life Animal Crematory (YD-50), y quiero conocer más detalles sobre:.
Dame la lista de precios exactos por support.
¿ Podría enviarme la lista de precios de muestras?Raw Medical Waste Incinerators. Can you please give a major cost quote for acquisition of (2) heaters, whichever version has a comparable Capability = 30 kg/hr.

Los quemadores kid Ecologicos. Me gustaría pedir algunas muestras. ¿ Podría enviarme la lista de precios de muestras?Raw Medical Waste Incinerators. Can you please provide a main expense quote for purchase of (2) burners, whichever variation has an equivalent Capacity = 30 kg/hr.



hospital incinerator

Supply, installation and testing of medical waste incinerator with a capacity of 75 kg / hr gas (LPG) complete with all accessories and consequently with the chimney in accordance with the technical specifications and conditions of public health
make a room for the incinerator that  accommodate three incinerators as in item 3.1.1 and attached to the  incinerator room   waste store that accommodate waste for a period of seven days and all the constructions of reinforced concrete with  preparingg  incinerator building  and store with all the work of wiring, electrical and lighting systems, water supply and sanitation
supply incinerator building and the waste warehouse with   a fire extinguish sprinkler system depends on the source of the water from network of teh general site , as well as a fire alarm system contains sensors for heat, smoke and  this system is linked with the hospital fire alarm systems
Supply, installation and testing of the ventilation system of the  incinerator room and the warehouse with  fans ROOF TOP EXHAUET FANS providing them with filters with high efficiency (HEPA FILTER ride to pull fans with taking the air change rate of 5 times per hour with streams and air required grilles
Supply, installation, testing separate conditioning unit for  waste repository DUCTED SPLIT UNITES and capacity sufficient to maintain the internal temperature at 14 degrees Celsius in summer and winter
Supply, installation, testing  of the cooling store of  insulated  prefabricated walls   inside the waste  room with a capacity of   35 cubic meters to save the medical waste at a temperature of zero Celsius till  burning  including the  cooling unit and all accessories
HAZARDOUS    wood
play wood
petroleum residual waste
hydraulic hose system
calcium hydroxide bags
bags or wooden boxes containing cyanide
medical waste
filters
pharmaceuticals
NO HAZARDOUS    sawdust
plastic
plastic and textil awnings
wood
plastic tubs
rubber
sanitary waste
EPPs
plastic bags
construction residual
contaminated rags or towels
plastic or packing of food
polyestirene dishes, glasses, spoon, fork, etc.Capacity incinerator medical waste to high combustion temperature
With a smokeless device to protect the environment and with two combustion chambers equipped with gas burners or oil
-incinerator to burn large volume pieces of 70 cm
deviation: Automatic Control System
-destructive capacity from 20 to 30 kgs
First-room / Temperature = 900 ° C combustion
2nd bedroom / Temperature = 1200 ° c afterburner

Solid Waste Incineration


Product Description

Incinerator is a incineration gear, direct fire waste by gasoline fuel or oi gas. As different circumscription, incinerator can be termed many words as below: 

Therapy ability: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator gas: Gas incinerator, oil incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

YDC incinerator is newest design for waste treatment, include health care waste, animal cremation and other solid waste. This gear quality structural for kinds of site, such as incinerators for animal waste sweden, incinerators for hospital wastes, incinerators for pets purchase, incinerators for poultry out of china, incinerators available kenya, hospital, environmental division, animal cremation bureaus, etc.. CLOVER Incinerator provide updated versions with dual combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

china medical burner



the complying with containerized burners. (Kitchen location as well as accommodations and grey water and black water plant eliminating waste) we need burner is each function various are done in one heater we require notified.
WASTE HEATERS SUGGESTIONS

china clinical burner Capability
? Disposal of both non-hazardous as well as infected products streams (per waste inventory).
?
Design/Specifications.
? Incinerators must have an added burning chamber with a minimum temperature selection of 900c.
? Liquid waste streams shall be blazed by a correct liquid shot system.
? The heaters will definitely be mounted with aesthetic alarm systems to indicate procedures of reduced temperature level in the secondary chamber.
Running Atmosphere as well as likewise Ambient Troubles

The Incinerators plan shall be developed to operate under the list below problems:.
? Ordinary Daily Max/Min June Temperature Level Level, 21-39 ° C.? Ordinary Daily Max/Min January Temperature Level Level, 2-12 ° C.
Medical waste heater,.
approx. 0.4 cubic metres,.
gas/ keys power operated,.
thermostatic temperature degree control,.
programmable cycle