Controlled air medical waste incinerator designed for incineration of All bio-medical waste


Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

Standards


Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Medical Waste Incinerators

Incinerator but the size of chamber > 2000 x >1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr.
Fueled by Heavy OIL Burner.waste disposal incinerator, capable of handling both wet and dry garbage.. Which include house hold wastes and dry leaves.
The chamber of the incinerator should be able to hold about 200 – 250 kilogram of waste at a given time. edical Waste Incinerators.
The mobile unit is our priority then the fixed units. Medical Waste Incinerators. The mobile unit is our priority then the fixed units.
a;  Batch Capacity for each model, how much load can we put in one time. I need tio under stand in term of batch load one time I can ut in Kgs.
b:  Burning capacity per hour, to know how much time it will take to burn one batch and what is cooling timem for each one.
c: How many batch can we put in each day basis per 24 hours.
d: Most of systems will be run on Gas, so I need to know the required pressure of gas in psi to run the system without any problem.
e; I do wish to know an average life of system and after how many years we need the repair of linning etc.

2. What is your minimum capacity and maximum capacity incinerator.

3. You do provide secodn hand incinerator in good working condition.
4. We need only double chamber double burner incinerator.
5. Please send us DEFRA and DADR approval reports by attachment, copy of ISO and summary of gas emmission report from incinerators.

installation of waste disposable incinerator system

installation of waste disposable system in airport.Incinerator with oil burner
Capacity  2 ton/day, Oil tank 300 l  Oil pump 0.4Kw , Burner 0.2Kw
Model : YD Series
Country of Origin : ITALY.-          Diesel incinerator.

–          25Kg/h. It will have mainly paper, cardboard and food, though also it will incinerate medical waste. So the incinerator shall be able to handle organic and hazardous waste.

–          Spare parts for one year.Burning Capacity: 400kg/ Hr ( Maximum Combustion time is 6 times/ Day)
Chimney External Diameter: not more than 400mm
Fan Power: must not exceed 1.1kw
Voltage: 220V
Oil Consumption: Must not exceed 14kg/hr
Feeding Door Width: not less than 1000x1300mm
Incineration Temparature: 800 Degree or above
Emission:
CO- Must not exceed 100mg/m3
SO2- Must not exceed 400mg/m3
HF( Hydrogen Flouride)- Must not exceed 9mg/m3
NO2- Must Not exceed 500mg/m3
Smoke Dust: Must Not exceed 100mg/m3

–          The design should prevent any release of polluting substances into soil, surface water and groundwater.

–          Combustion zone has to reach at least 860 degrees under the most adverse conditions with at least 6% oxygen. Since it will treat hazardous and organic waste, temperature has to reach at least 1100 degrees for at least 2 second.

–          Flue gases must be cooled to 200 degrees or lower before flue gas treatment. The flue gas cleaning equipment maust be at least two-field electrostatic precipitator/ESP, dust <30mgNm3.

–          Thermal efficiency not less than 85%.

–          It should be equipped with filter to reduce and contain pollutants from organic and medical waste.

–          Easy to operate for almost unskilled workers.

diesel oil fired medical waste incenerator


High Temperature Waste Incinerator Model D. MB 750XL Burn Rate-150Kg/hour minimum Weight(Kg)-4000kg Secondary Chamber

(double chamber with post-burning) Gas Retention Time 2 second Fuel Diesel Power Supply for control box 220V-240, single

phase 50-60Hz Minimum operating temperature 1200 oC One year spare parts package for complete maintainability 10m hose

pipe. 1100 litre fuel Tank +pipe system Containerised (the container will serve as housing) Additional chimney extension

1 metre high One (1) year warranty.

Incinerator of 20 Kg : 03 Units

Electrically controlled incinerator.

Two-compartment incinerator with a capacity of 20 kg / hour.

Incinerator with low maintenance and operating costs; Equipped with an automatic control panel and easy to use with

electromagnetic locking of the door.

A main waste reduction chamber of 900 ° C. A post secondary combustion chamber of gases generated in the primary chamber

at least 1100 ° C.

Carbon residues in ash less than 5% by weight in accordance with European Directive 2000/76 / EC.

With refractory lining in materials of higher quality
1/ Cost of a 200kgs/Hr medical waste incinerator.
2/ (CIF Term) Cost of shipping from factory to PAPUA NEW GUINEA seaport of LAE, Morobe province
3/ Cost of 2 Clover engineers to Supervise, Installation, Training our engineers and commissioning the medical; waste

incinerator.


pet burners up for sale



SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE
? Quantity: 20 systems
? The Burner collaborates with a 55 gallon open ended up steel drum
? The system operates without fuel as well as used just 120v or 220v electric power for the blowers
? Unit can melting oil contaminated waste and additionally medical wastes with a wetness material of 0 to 15%.
? Each device is offered with 2 steel drums, to make certain that an extra is conveniently available.
? Each unit to be given with suggested spare elements.
? Solution warranty– – minimum one year from billing as well as authorization.
? Individual’s guidebook to be supplied in French and also English

HAZARDOUS WASTE TO BE INCINERATED

Unsafe Strong Chemicals.
Various kind of combustible solids, taken advantage of fabrics, oil and printer toner cartridges, chemicals for water filtration and also image consumables, as well as plastic product, vacant steel/ plastic cans that still have deposits of hazardous items, oil absorptive

Risky Fluid Chemicals.
Primarily numerous kinds of Acid, Paint, Varnish, White Spirit, Aromatic-Less Solvents, Artificial Fluid For Brake Solutions, Airplane De-icing Liquid, Hydraulic And Likewise Compressor Oil, Freon made use of in some older refrigeration systems, Chemical Liquid/Spray, Air Refresh Spray and also various other comparable chemicals

Contaminated Gas.
Primarily diesel or gas infected by water or solvents

Made use of and/or Polluted Oil.
Utilized electrical motor oils and/or mineral oils unfit for their initially implied usage. Usually motor/gear box oil (approx. 80%) contaminated by a combination of white spirit and additionally acetone (approx. 5%) hydraulic liquid (approx 5%)

Polluted Water.
Waste oils/water, seeps, hydrocarbons/water combinations, solutions as well as likewise leachate

Infected Dirt.
Dirt polluted by oil gas of chemicals,.
Soil infected that needs to be reused in garbage dump,.
Dirt dealt with along with transformed on website

Oil Polluted Solids.
Fabrics, absorbents, cardboard, oil and also gas filters, air filters are not considered as dangerous products

Digital Waste.
Waste electric or digital setups or appliances up, including published circuit card having dangerous product and/or significant steel and/or releasing minimized radiation

Used Battery Cells.
Dry battery, ups battery or various other kinds unsorted waste batteries/battery cells, having items that are hazardous

Used Lead Acid Batteries.
Waste lead acid batteries, drained pipes/ un-drained as well as whole or wrecked

Hazardous Medical Waste.
Scientific along with associated waste arising from clinical, nursing or comparable techniques and also waste created in facilities throughout the examination or treatment of individuals (biography risk)

Finished Medicines Strong.
Waste medications, medicines along with drugs, consisting of delicate medicines

Ran out Medicines Fluid.
Waste liquid pharmaceuticals, different kind liquid chemicals for treatment, medical oil in addition to paraffin based finished drugs

Finished and/Or Infected Food.
Spoiled fresh food or meaningless recipe prepared to consume dishes (MRE’s) entirely dry food



Burners at 3 centers to improve medical care waste


a. 2.5 statistics tons daily healthcare waste burner

b. 1.5 statistics stacks daily healthcare waste heater

c. 300 kg daily medical care waste heater

Our recommended technology is double-chamber incineration, but should you recommend a different modern-day technology, that’s okay.

We request information about the adhering to for all the aforementioned needs:

1. Resources cost (offered cost in Oman)

2. Operation in addition to upkeep costs (annual )

3. Amount of drivers asked for

4. Item specs (measurements, temperature level degrees, home time, cycle time )

5. Numerous other complementary equipment That’s required or advised from you


Incinerators


Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Key Features:  * All versions with Dual combustion room.  *based on order  * High temperature, long lifetime of incinerator.  * Free or minimum installation on site.  * High speed, from 10kgs to 500kgs per hour, up to 6ton per day.  * PLC Control Plane. *based on order  New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES