medical waste incinerator china


medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: –

·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste

·         Waste density: 125 to 350Kg/M3

·         Waste CV: 4000 KCAL/kg

·         Moisture content: 10-25%

·         Estimated ash residue: 5-10%

·         Nominal capacity: 30Kg/hour batch load

·         Secondary chamber: 0.5 second @ 850oC
·         Compact laboratory style

·         Two combustion chambers

·         Ecologically friendly

·         Up to 50kg of waste / hour

·         To be used for animals


Incenorators for Pets


Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover
Origin:Nanjing China

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Key Features:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control Plane. *based on order  New Design for pet animal cremation business.  * One year guarantee on incinerator and components in stock. 

Application Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

Nanjing Clover Medical Technology Co., Ltd.  Tel: +86-25-84610201  Fax: +86-25-84610406

pet crematory


The temperature is over the minimum and under the maximum required temperature (e.g 1150?C) of the thermal

reactor (partial load).

 

When switching off, only the solenoid valve for the fuel supply closes, the burner fan stays on to cool and protect the

burner head.

 

The reactor burner shall be modulating burner with pre-ventilation working on the principle of an oil pressure atomizer

with return nozzle for diesel oil, consisting of:

 

–      Fan housing with high-powered fan and cover

 

–      Electric motor

 

–      Oil pressure pump with built-in oil pressure controller

 

–      Burner nozzle rod with return nozzle and baffle plate

 

–      Coupled control with servomotor, rate controller, regulating segment and air valves

 

–          Electromagnetic shut-off dampers

–      Burner tube with flame pot, burner connection and insulation flange

 

–      Electrical high voltage ignition with ignition transformer and ignition electrodes

 

In the control panel:

 

–      Oil firing sequence control automation relay.

capacity – 50 Kg

 

Burn rate – 20 Kg/h

 

maximum Temperature – 1000C

 

Operating Energy – Diesel

 

Ignition method –

 

Combustion chambers – 2

 

Insulation – refractory Lining

 

No of burners – 2

 

Loading Method – Front load with safety latch

 

Chimney – Heavy duty stainless steel

 

Control – Burner control

 

Thermostat control

 

Timer control

 

Fan timer control

 

Instrumentation -4 Digit temperature display

 

Ash removal – Separate ash removal door

 

Fuel consumption per Kg –

 

Automatic & simple to operate control pannel –

 

3 mm steel casing & fully insulation

 

Dense  refractory concrete lining rated to 1400 degree to C

 

safety chute for easy loading –

 

SS Flue as standard –

 

Heat recovery option –

 

Easy onsite Installation –


animal waste incinerator


secondary chamber

1000 degree

 

chimney

standard

 

shredder

separately

 

Autoclave or microwaves

separately

 

temperature monitor

attached outside of machine

 

operating

Fuel and electric

During the start and end incineration operations at the waste incineration plant the temperature shall be maintained

at 850 °C, while it shall be 1100 °C when incinerating dangerous waste containing halogenated organic substances with

content of chlorine or its compounds. The temperature shall be maintained at 1000 °C during incineration of medical

waste.

MUNICIPAL SOLID WASTE INCINERATORS

 

Municipal waste incinerator quantities and capacities shall be designed for 24-hour 7-day-a-week continuous operation.

 

Incinerators shall be capable of processing both wet and dry material and operating on either diesel fuel, JP-8 fuel,

 

or waste oil; see Plumbing for fuel storage system requirements. The following shall be provided as a minimum:

 

Reinforced concrete mounting foundations, feed or charging hoppers (or loaders), primary combustion chambers

 

with ash cleanout doors, secondary combustion chambers with ash cleanout doors, cyclone air filters (or separators),


incinerator manufacturers


GOODS:  ONE INCINERATORS IN ACCORDANCE WITH THE   SUPPLIER’    
REQUIREMENT     S OWN    
        PROPOSED    
           
        SPECIFICA    
        TION/      
        CONFIRM    
        ATION    
        SPECS    
  Height from base: 11m and if there are buildings within 30m of the          
  incinerator, chimney must extend at least 3m above the apexes of all          
  the roofs of such buildings            
  Diameter of chimney at top: 430mm          
  Weight of stack: ± 500kg            
  case and stack be painted with 400 °C heat resistant black paint          
  Burners            
  1st chamber 850 oC -900oC            
  2nd chamber 1000oC            
  Variable speed combustion air blowers          
  Primary chamber volume ±1.05 cubic metres          
  Mixing chamber volume ±0.30 cubic meters          
  Settling chamber volume ±0.89 cubic meters          
  Weight excluding chimney ±6 400kg at manufacture          
  Firing tools supplied: Hoe, poker and rake          
  Dimensions            
  Length ±2 125mm            
  Width ±1 890mm            
  Height  ±2 125mm            
  Extra width for burners ±1 000mm          
  Loading door opening 610mm×540mm          
  Hearth area ±1.19 square metres          
  Description of grate/hearth: A full hearth to be supplied to prevent          
  contaminated  liquids  from  flowing  into  ash  pit  without  being          
  incinerated            
  Compliance with South African Atmospheric Pollution Prevention          
  Act No. 45 of 1965 or equivalent air pollution standard          
  Documents to be supplied : Operations and maintenance manual and          
  standard operating procedures (SOPs)          
  Emission controls:            
  heated refractory screen            
  Low velocity grit settling chamber          
  Stainless steel arrester screen            
  Refractory material: alumina content ≥49% and thickness average          
  102mm            
  Bake out: to be done over 2-3 days          
  Materials of construction            
  Case: 5mm mild steel            
  Bracing: heavy angle and channel          
  Hearth: 1550 °C            
  Ashing door: high grade cast iron          
  Loading door 5mm mild steel lined with 1550 °C castable general          
  purpose high strength, high abrasion resistant monolithic refractory          
  concrete            
    36        


medical waste incineration monitoring



All kindly animals owners wish their wonderful pet dog or feline be in heaven after they leave us. We comprehend the special bond in between pet dog and also owner and also believe that it must never ever be forgotten. Shedding a pet can be ravaging and also we developed our business so family members can remember their pet dogs forever.incineraters, pet dog cremation business, cannabis waste elimination, local waste burner, veolia incineratorhospital waste incinerator, hazardous waste incineration, gas incinerator, incineration garbage disposal

The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world. 



Heater ability of devastation of 350 kg/hour


– – – – – – – – Waste will probably be automatic feeding system directly into the burner.

– – – – – – – – Control plank will absolutely be fitted using a beneficial synoptic view disclosing the operating scenario of the entire

heater as well as also cared for by DCS/PLC system.

– – – – – – – – Heating system will certainly be made as a Packaged method, having electrical web link last as well as pre-wired pipes

in placing.

– – – – – – – – Control plank will absolutely be fitted using a valuable synoptic view disclosing the operating situation of the entire

heating system as well as likewise taken care of by DCS/PLC system.

– – – – – – – – TOC of slag as well as bottom ashes will absolutely be much less 3% of the completely dry weight.

– – – – – – – – Heater will surely be created as a Packaged system, having electric connection pre-wired as well as last pipes

in positioning.

– – – – – – – – Burner will surely have automated de-ashing system with higher instructions.

in position.

– – – – Incinerator will possess automated de-ashing system with upward direction.

– – – – Burner will surely have flue gas therapy system comprehensive [emergency scenario by-pass heap, gas heating system,

two activators as well as additionally particulates filtering method ] as well as assurance of discharges out of burner.

– – – – Training of AKU workers at website.

– – – – website could be assessed as well as likewise take a look at existing ATI maker, capacity 150 kg/hr. In 1 day therapy.

– – – – Existing facilities space is conveniently available in basement, 100′ ′ Size x 30 ′ large x 20 ′ Altitude for 2nd Incinerator.

– – – – Existing smokeshaft dimension is 12 meter, and additionally size is 24″ ″ dia.

common daily bloodbath involves 120 pigs. The Condemned thing along with additionally results in the abattoir for Entry is around 1000 kgs.daily{
(adsbygoogle = window.adsbygoogle || []).push({});|}


small scale medical waste incinerator

Toxic and dangerous wastes,
Medical pharmaceutical and hospitable liquids  Wastes
Domestic garbage
Electric and electronic wastes
Industrial wastes
In General, all type of wastes and garbages
Capacity 50-60Kg/h

Combustion supporting materials
Coal oil, diesel oil

Temperature inside
800-10000C

1000-12000C

Burning efficiency
>98%

Power consumption
1.3KW

Noise
<78dB

Index of let smoke and waste gas
Ringelman’s smoke index< level 1

Smoke concentration
Oil
45.5

(mg/m3)
Gas
25.5

(mg/m3)

SO
Oil
0.176
Gas
0.065

NOX
Oil
0.031
Gas
0.038

H2S
Oil
0.016
Gas
0.008

CO
Oil
8.32
Gas
35.64

small scale medical waste incinerator Requirements
Incombustible and explosive materials not allowed in

Process manner
Two combustion cabinets (wetness drying, high temperature dust removal)

Combustion / Burner
Good Quality made in Italy

Blower
Good Quality made in China

Control Electrical
Good Quality made in China

Capacity 50 Kg/h

Working Voltage
220 V

Power
1000 W

Applied For
200 beds

Input Fashion
Manual

Medical Incinerator, 24 kg/hr
Medical Incinerator, 24 kg/hr including panel board, controls and accessories
Furnace gate
Chimney
Blower
Combustion burner

Medical Incinerator, 12 kg/hr
Medical Incinerator, 12 kg/hr including panel board, controls and accessories
Furnace gate
Chimney
Blower
Combustion burner

Medical Incinerator, 6 kg/hr
Medical Incinerator, 6 kg/hr including panel board, controls and accessories
Furnace gate
Chimney
Blower
Combustion burner