Medical Waste Incineration Plant


Product Description

Nanjing Clover Medical Technology Co., Ltd..

Item Specification
Model TS50 PLC
Main Product List per 01 set Primary Combustion Chamber
Secondary Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Case
Chimney:5.0Meters
*(upgrade to Stainless Steel, free cost)
Italyoil/gas burner: 02 units
Oil Tank (if oil fuel): 100Liters

PLC( Programmable Logic Controller), Smart and Automated operation. Set combuston time based on different waste material and incinerator cease combustion .

Waste Incineration Therapy BURNING PRICE: 100-150kgs per hr HICLOVER TS150


BURNING RATE: -100 -150 kgs per hour

MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING)

MAX OPERATING TEMPERATURE LEVEL: 1000-1200 oC (AFTER HEATER BURNING)

SECONDARY MELTING CAPABILITY: COMPULSORY

DENSITY INSULATION: 50 mm high

Refractory capability: minutes 114mm

STURDY REFRACTING LINING TO WITHSATND 17500C

AVEARGE BURN OUT TIME: MAXIMUM 3HRS

GAS TYPE: FUEL OIL (DIESEL)

FUEL INTAKE IN LTRS/HR: average 14

RESIDNECY TIME IN SECONDARY CHAMBER: 2 PHASES

Items/Model

TS150( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Price

Standard 100-150 kg/hour

Feed Capability

Standard 750kg/feeding

Control Setting

PLC( Programmable Reasoning Controller Incinerator)

Chamber Material

High Alumina Fire Brick Wall, 1750 ℃ Rate

Paint for outdoors face

800 ° C Price

Burning Chamber

1570L

Inner Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Guidebook

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Consumption (Liter/hour)

Ordinary 14( D.O)

Gas Intake (m3/hour)

***

Temperature Screen

Digital Show

Temperature Level Defense

Yes

Oil Tank

2000L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without chimney)



HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28


animal incinerators


The incinerator shall be equipped with a Diesel oil tank that will be supplied with DO from our DO tank located in the

power station. The tank shall be equipped with level switches and appropriate solenoid valves for automatic filling of

the tank. The tank shall also be equipped with a magnetic level indicator, level switches and appropriate drain valves,

separate overflow and vent pipes.

Oil-fired multi-stage waste incinerator of pyrolytic type shall be installed complete with interconnecting flue gas

ductwork between the incinerator and the chimney outlet.

 

The unit shall be manufactured in accordance with the latest ASME code, BS and DIN standards.

 

The waste disposal shall be environmentally acceptable and the incineration emission shall comply with the admissible

emission limits (international EC-Standards). The visibility of flue gases shall not exceed one Ringelmann. The waste

shall be completely burnt and the content of un burnt organic matter of the ash shall not exceed 3%.

 

The unit shall allow for a minimum of 2.0 seconds retention time.

 

1.2        QUALITY ASSURANCE:

 

  1. Coordinate the entire assembly of incinerator, stack, controls, fuel supply.

 

  1. Provide written certification that the entire assembly has been coordinated to achieve the required performance

and to provide the required features.

 

  1. Equipment, installation, and operation shall conform to NFPA 82. Where conflicts exist between NFPA 82 and this

specification, this specification shall govern.

 

1.3        SUBMITTALS:

 

  1. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

 

  1. Incinerator:

 

  1. Arrangement, description of construction, and outline drawings of incinerator and accessories showing

clearances and dimensions.

 

  1. Predicted performance including burn time based on waste composition specified.

 

  1. Calculation of secondary chamber retention time.


small scale incinerator


A chamber of article combustion of gases
Electric box

The secondary combustion chamber must ruin the contaminant merchandise and must withstand to high temperature(1100 °C)

Process Filtering method: Scruber to be mentionned as optional

A change circuit breaker for each engine (ventilators and burners).
OA device of injection of air allowing a entire recombustion of gases,
OA device of air ducts of cooling of waste gases,
O Composition of this refractory;

? Refractory concrete :
OA sheath of evacuation of the gases burnt.
OComposition of this refractory;
?
.

The incinerator shall be completely self contained.

The incinerator plant shall incorporate a control panel for its own operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and track the incinerator and his performance.

Ability of jealousy in weight shall be 60 Kg/h.

it ought to be able to operate less than 10 hours/day

This incinerator needs to have the ability to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator must prevent the release of black smoke and dust that is fine, throughout the loadings.

It shall have the ability to decrease the volume of wastes from 98%.

It shall have the ability to hold emission at the next burn with gasoline residence of less than 2 seconds.

The incineration should be completely free from visible smoke in addition to offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

the principal combustion chamber shall be built from heavy steel plate and the unit is lined with a complete layer of hote face refractory and higher performance insulation.

The Inner Width of the Chimney at least:? 400 and its elevation: 8 m

The loudness of the combustion chamber at least: 1.200 L

The Dimension of this door for loading in cm at least: 70×70.

Burner surgery ought to be Automatic On/Off
? Nature: Calcium
Fuel? : diesel

Manufacturer to provide  necessary information to your best of  this setup

The control panel shall have all appropriate audible and visual alerts to guarantee safe performance.

This incinerator with”PYROLYTIC” combustion must possess:
OElectro-ventilator distributing the secondary air, the regulation of the air flow has been completed by valves and adhering to the constraint of the automatic cycle.
?
.
OA secondary shot of air to guarantee perfect oxygen content.

A controller box ensuring the whole cycle of combustion.

Fan:

A chamber of post combustion of gases
oA burner of combustion of gases,
oA device of injection of air allowing a total recombustion of gases,
oA device of air inlet of cooling of waste gases,
oA sheath of evacuation of the gases burnt.
oCarcass in strong sheet steel with support of connection.
oComposition of the refractory;
?Refractory concrete :
?Thickness    : ≥150 mm
?Nature: 65% of Al203
?Insulate in fibrous panel :
?Thickness: ≥85 mm
? Nature: Calcium
oBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
oA secondary injection of air to ensure perfect oxygen content.

A control box ensuring the complete cycle of combustion.

Fan:
oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
Controls and regulations:
Control box watertight to dust, including:

A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post combustion.
Electric box

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional


Incinerator Medical Waste Maximum Capacity


Basic Info.

 

Model NO.:medical waste incinerator manufacturers
Export Markets:Global

Product Description

 

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China.

Key Attributes:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  * New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and components in stock. 

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4.

HICLOVER Incinerators

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We provide single combustion chamber, dual glazing chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, hospital, clinic, medical centre, hygiene clinical waste destruction with medical disposable, biological waste, and medical plastic waste, and hazardous waste, and red bag waste, and needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc..

Our assortment of incinerators cater to small to large scale animal cremation associated businesses, including poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.
The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.
The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

We’re china incinerator manufacturer, builder and exporter.  Manufacturer make fair price for incinerator consumer, provide medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, little incinerator, pet incinerator, animal incinerator, mobile incinerator, little animal incinerator, infectious waste pyrolysis machine, laboratory incinerator.  HICLOVER help customer decrease buy budget, custom made purpose, quality merchandise and friendly support.

 

Tel: +86-25-84610201 Email: [email protected]  Website: www.hiclover.com
Key Features:

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.

— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.
— HICLOVER, trusted partner with years of experience.
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm

Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 200L 300L 500L 500L
Feed Door 80x60cm 80x60cm
Chimney 10Meter 10Meter 14Meter 14Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 6000kg 8500kg 11000kg 16000kg
External Dimensions 260x150x180cm 300x160x190cm 400x210x300cm 450x210x300cm

waste incinerator manufacturer in china

  1. Burning rate: 250 Kg/hr.
  2. It should be able to Operate not Less than 10 hours/day
  3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
  4. Design Specification: Types A, B, C, D, and E of medical waste
  5. “PYROLYTIC” combustion, by controlling the gasification of waste.
  6. The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
  7. It should be able to reduce the volume of wastes by 98%.
  8. It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be completely free from visible smoke as well as offensive odours.

  1. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
  • The Temperatures of combustion:Minimum will be 850oC and max 1400oC
  • Post combustion: >1100o
  1. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter
  2. The Volume of the combustion chamber: Not Less Than 2.3 M³
  3. Burner operation should be Automatic On/Off
  4. Fuel : diesel, LPG, Natural Gas, Bio fuel
  5. The supplier must provide  necessary information for the best of  the installation

This incinerator with “PYROLYTIC” combustion must have:

  1. A combustion chamber of waste:

* Perfectly tight door for the manual loading of waste.The loading should be Manual, Batch Load,

* A burner of lighting which the use is limited to the ignition of waste.

* Top Loading loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.

* Composition of the refractory;

  • Refractory concrete :
    • . Thickness : ≥100 mm
    • . Nature: 42% of Al203
  • Insulate in fibrous panels :
    • . Thickness: ≥75 mm
  • Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

  1. Load Method: Top Loading

 

  1. A chamber of post combustion of gases

* A burner of combustion of gases,

* A device of injection of air allowing a total recombustion of gases,

* A device of air inlet of cooling of waste gases,

* A sheath of evacuation of the gases burnt.

* Carcass in strong sheet steel with support of connection.

* Composition of the refractory;

  • Refractory concrete :
    • Thickness : ≥180 mm
    • Nature: 65% of Al203
  • Insulate in fibrous panel :