Product Description
Q: What’s kind of waste may use within this gear? A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid waste and gas waste. GB18484-2001.
Q: Remedy capacity A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time to get feeding waste. Burning incenrator manufactuer, burning medical waste, burning waste chamber, purchase a mobile crematorium, purchase a small incinerator, purchase creature cremation systems, Real combustion time per day is around 16 hours. The life of incinerator involving 5-10 year according to use.
Ordinarily, we proposal small lab, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please compute the waste output around 2kgs per individuals every day. If there are 200 sickbed in the hospital, that's imply you need one incinerator capacity around 400kgs every day, switch to capacity per hour is around 30-40 kgs per hour. According the operation time every day, waste material, funding, growth, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We provide all documents and incinerators simple to installation and operation. Customer can send individuals come to our factory to find out operation and installation. Generally, We do not send engineer to local website if not request. The dispatch price is additional according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode according to model and order.
One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection component.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model |
YD-10C |
YD-20C |
YD-30C |
YD-50C |
Burning Rate (kgs/Hour) |
10 kgs/Hr. |
20 kgs/Hr. |
30 kgs/Hr. |
50 kgs/Hr. |
Feed Capacity (kgs) |
40 kgs |
40 kgs |
50 kgs |
80 kgs |
Equipment Weight |
1200 kgs |
1200 kgs |
1800 kgs |
2200 kgs |
Primary Chamber (Liters) |
200 |
200 |
250 |
400 |
Secondary Chamber (Liters) |
140 |
140 |
140 |
140 |
External Dimensions (cm) |
170x140x160 |
170x140x160 |
170x140x190 |
180x160x200 |
Internal Dimensions (cm) |
55x55x65 |
55x55x65 |
55x55x85 |
70x70x85 |
Oil Tank(Liters) |
50 |
100 |
100 |
150 |
Door Opening (cm) |
38 x 48 |
38 x 48 |
38 x 48 |
45×55 |
Chimney (M) |
5 |
5 |
5 |
5 |
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Secondary Chamber |
YES |
YES |
YES |
YES |
Mix-Combustion Chamber |
YES |
YES |
YES |
YES |
Smoke Filter Chamber |
YES |
YES |
YES |
YES |
Combustion Fuel |
Oil/Gas |
Oil/Gas |
Oil/Gas |
Oil/Gas |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Temperature Monitoring |
YES |
YES |
YES |
YES |