Healthcare facility for melting hazardous waste in addition to chimicals


usage from the hospital for burning hazardous waste in addition to chimicals, minimal Ability 300 per hr. I’ll be marketing to my customer? . Below is the advice I had been given and absolutely nothing else. The hospital burner for usage in the professional squander as called for by worldwide ecological management. Minimum 300 Kg capacity/hr, Gas discharged, refractory lined, smokeshaft in addition to tasting prot. Minimum temperature of 1100 level Celsiu.the incinerator apparatus for discard 500kg per hour. Job concerning shed medical waste of those hospitals.Just need to rate of you different kinds of Medical Rubbish Incinerators.need all information on 300 kg per hour system. accessibility. Functional costs using diesel (different other). The waste is Individual Cells. And we’ve got 10 kg each day; we need burner for clinical waste.Burn Capability: 50kgs per hr (Regular capacity according to Medical Waste). Please forward information regarding prices on every one of you pet crematory models.Regarding Gas Incinerator, Please be aware that Fuel for the Incinerator
Will be Gas. As gas is processor in our nation.


Hospital Medical Waste Incinerators


Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks 7m3 4500 kgs Shanghai Port
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks 10m3 6000 kgs Shanghai Port
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks 13m3 7500 kgs Shanghai Port
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 3m3 1200 kgs Shanghai Port
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 6m3 2000 kgs Shanghai Port
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 7m3 2300 kgs Shanghai Port
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5m3 2300 kgs Shanghai Port
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks 3m3 1500 kgs Shanghai Port
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks 8m3 4500 kgs Shanghai Port
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 13m3 6000 kgs Shanghai Port
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 17m3 7500 kgs Shanghai Port
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil 10sets/2 weeks 20m3 9000 kgs Shanghai Port
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil 5sets/2 weeks 27m3 13000 kgs Shanghai Port
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks 28m3 7000 kgs Shanghai Port
HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


Afterburner Preheat Heater



PRIMARY CHAMBER

Durable steel casing

Top-notch refractory cellular lining and also insulation Large complete measurement leading loads counteracted door
1 x oil/gas terminated ignition burners ran on/off

SECONDARY CHAMBER

Tough steel casing

Premium refractory lining as well as also insulation 2 second gas residence time
1 x oil/gas discharged ignition burners ran on/off

SMOKESHAFT

Heavy-duty stainless steel casing

CONTROL BOARD

Control of primary along with 2nd burners Temperature degree Talking to 4 figure display screen Thermostat control tool for heating system (gas saver) Timer control 0- 12 hrs

Important follower timer control

Technical Specs

Gas
Diesel

Ability
900kg (1.35 m ³)

Burn Rate
150kg/h

Avg Ash Residue
3%

Avg Fuel Consumption p/hr
20ltr

Operation
Minutes. Operating Temperature 950 ° C. Max. Running Temperature Level 1320 ° C. Residency Time in Second Chamber 2 Secs.
Temperature level Tracking YES

ANCILLARIES

Operating and maintenance guidebooks Conserves list

TRICK FEATURES

– – Afterburner Preheat

– – Incineration temperature degrees over of 1300 ° C

– – 5mm steel covering as well as totally shield

– – Dense refractory concrete lining rated to 1600 ° C



laboratory natural waste incineration



1- There are greater than 4000 Cubic Meter sludge are packed in Plastic Bags & & & & maintained more than ten years
2- Cleaning up and also taken care of 2500 Cubic Meters inside the Oil Tank.
– – – – the waste is organic as well as originating from laboratory, can be greatly dangerous in instance of terror strike or booms or comparable events.
– – – – the input is lowered in addition to periodic, the research laboratory is made use of when horror or epidemy security system occures. However occasionly incineration of human or animal carcasses can be demanded.mobile burner to function along with a mobile biolab for really first responders.is the tiniest burner readily available in the market. incinerator of abilities of 10kg/h as well as 20 kg/h for medical care center waste.



Diesel Fired Waste Incinerator


Basic Info.

Type:Incinerator
Export Markets:Global

Additional Info.

Trademark:CLOVER CHINA

Product Description

Key Features:  * All models with Dual combustion chamber.  *based on sequence * High fever, long lifetime of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  * PLC Control Plane. *based on order  * New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Pet Crematorium Equipment


Basic Info.

Model NO.:pet crematorium incinerators china price
Export Markets:Global

Product Description

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

FAQs


Q: what is kind of waste can use in this equipment?

A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.

 

Q: Incinerator Smoke Standard

A: China Government Standard: No.GB18484-2001.

 

Q: Treatment capacity

A: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.

 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.

 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.

*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.

 

Q: Assembly and Testing

A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order.

 

Q: Combustion Temperature

A: The first combustion chamber: 800-1000 centi degree.

The second combustion chamber: 1000-1200 centi degree.

 

Q: Incinerator Control Mode

A: Default Control mode is common control case. PLC mode according to model and order.

 

Q: Operation and maintenance costs

A: Operation cost according to fuel consumption rate and power/staff, etc.

 

Annual around $500-$1000usd per year maintenance according model, use situation.

 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.

 

Q: The Residency time in secondary combustion chamber

A: 02 sec.

 

 

 

 

 

 


china medical waste incinerator


Incinerate: medical waste and general waste

Capacity to burn waste: 400 — 500 kg/hr

Fuel: Diesel

Fuel Consumption: 10 litres/hr maximum

Incineration temperature: 950 – 1300 °c

Casing: thick (min 5 mm) Stainless steel casing and fully

insulated to withstand sea humidity

Voltage: 220/240 V or 380/415V

Frequency: 50 Hz

Feeding: automatic

Ash 1 leftovers removal: Automatic

Fuel gas filtration system: Yes

Warranty: 12 months

Staff training: Operator & Maintenance staff

Operation and service manuals: 3 sets each

 

  • With Chassis to be Mounted in truck/lorry

 

  • May have a primary and secondary combustion chamber

 

  • Must have a dilution chamber

 

  • Capacity: 100 Kgs per hour

 

  • Power Source: Diesel or Natural Gas or Liquified Natural Gas

 

  • General wastes produced on a daily basis include paper, plastic, organic materials, boxes, plastic

containers, leaves, etc;

1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be

regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement

device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a

separate forced draft fan accounting for the air supplied through burners. Provision shall be made in the primary

chamber to measure the water column pressure.

  1. Capacity : up to 4000kg burn not less than 500 kg /hr
  2. The refractory lining of the chamber shall be strong enough to sustain minimum temperature of 1000dc in the primary

chamber and 1200 dc in the secondary chamber. The refractory& insulation bricks shall have minimum 115mm thickness each

& conform to IS:8-1983 & IS:2042-1972 respectively.

  1. The incinerator shell shall be made of SS/MS plate of adequate thickness (minimum 5mm) and painted externally with

heat resistant aluminium paint suitable to withstand temp.of 250 dc with proper surface preparation. Refractory lining

of the hot duct shall be done with refractory castable (minimum 45mm thick)& insulation castable(minimum 80mm thick).

Ceramic wool shall be used at hot duct flanges & expansion joints.

5.There shall be a separate burner each for the primary & secondary chamber. The heat input capacity of each burner

shall be sufficient to raise the temp.in the primary & secondary chambers as 800+/- 50dc and 1050+/-50dc respectively

within maximum of 60 minutes prior to waste charging. The burners shall have automatic switching off/on control to

avoid the fluctuations of temperatures beyond the required temp.range.

6.Incinerator shall have graphic or computer recording device which shall automatically and continuously monitor and

record dates, time of day, batch sequential number,Co,Co2,O2 in gaseous emission shall also be  measured daily.

6mm plate steel sheel construction

11cm 1400 o C Refractory L iner

Temperature controlled Burners

Secondary combustion Burners

Interlock Switch on Load Doors

Separate Ash Door

One Second secondary Residence @ 1000 o C

400 ° C Silicone Based Paint Finish.

Alloy Temperature Sensor

Factory wired and tested

Capacity-20 kg / hr

Primary Chamber-1607 L

Hearth Area-1:36 sq. m

Secondary Chamber-694 L

Primary Burner (oil)-420,000 btu

Secondary Burner (oil)-900,000 btu

secondary Combustion-1/6 hp

Exhaust Stack-46cm x 6m

Electrical Service-220/50

Weight System-5.700 kg

Dimension “D”-152cm

Load Port Height- 60x 60 cm

Ash Port Height -36 x 36 cm

  1. Structural design of the chimney/stack shall be as per IS:6533-1989.The chimney/stack shall be lined from inside

with minimum of 3mm thick natural hard rubber suitable for the duty conditions and shall also conform to IS:4682 part

I-1968 to avoid corrosion to oxygen and acids in the flue gas.

INCINERATEUR DE DECHETS HOSPITALIER