Waste Kind: health care waste
Throughput: 50kg/hr at a nominal calorific value of 4,000kca/kg along with an average bulk density of 120kg/m3 for overall waste and 160kg/m3 for healthcare waste.
Coaching: the Agent will conduct a 2 days incinerators training following installation and commissioning of the equipment.
The Agent shall conduct a 2 days operation & maintenance training into the Biomedical engineering personnel following installation & commissioning of the equipment.
It is carried from the ground level on a considerable steel support frame. Internally the shell is lined with calcium silicate insulation and a hot face mixture of super obligation brickwork or higher strength castable.
the principal combustion chamber must ensure minimal exit temp is not significantly less than 850? C.
Waste density: 125 into 350Kg/M3
Main Combustion chamber:
Flue gas treatment: should have particulate remover (scrubbers)
Limiting continuous service limitation 1500? C
Chamber: should really be refractory lined into the following standard;
Chimney/Stack: If be made from refractory lined mild steel or higher quality air-cooled s/s.
Medical waste incinerator for sale Operation manual: 2 sets
Burner: arranged for on/off operation
Fully packaged oil kind, complete with electric ignition and flame failure controls, wired with continuous running enthusiast and finish with valves, fan and motor.
Secondary room: 2 [email protected]? C
Average consumption: at least 4.5Ltrs/hr
1 off diesel-fired ignition burner — temperature controlled