Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize within this gear? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid gas and waste waste. GB18484-2001.
Q: Remedy capacity A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t indicate any waste material. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator utilize time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time daily is about 16 hours. The life of incinerator between 5-10 year based on utilize.
Ordinarily, we proposal small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, that's imply you need one incinerator capability around 400kgs daily, change to capacity per hour is approximately 30-40 kgs per hour. According the performance time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs each hour incinerator. *The best way to calculate Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We supply all files and incinerators easy to installation and functionality. Customer can send people visit our factory to find out operation and installation. Generally, We do not send engineer to local site if not ask. The dispatch cost is additional based on order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi level. The second combustion chamber: 1000-1200 centi level. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD per year maintenance according version, use situation.
One individual can service 02 device incinerators. China animal cremation, china incinerator supplier, cloverincinerator, backyard incinerator, hog incinerator, infectious waste pyrolysis machine china, ” The team should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, also understand threat of medical waste to safeguard worker self with essential protection element.
Q: The Residency period in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |