Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste may utilize within this gear? A: This gear for medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not mean any waste material. The animal/pet combustion rate around 2/3 of ordinary capacity.
Clover incinerator utilize time per day up to 24 hours. Between each feed/combustion time, you will find about 0.5-1 hours cooling time and time to get feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator involving 5-10 year according to utilize.
Ordinarily, we proposal small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output around 2kgs per individuals every day. Medical waste furnace, animal waste incinerator manufacturer, domestic incinerator, incinerator installment demonstration, medical incinerator prices, in case there are 200 sickbed in the hospital, that's mean you need 1 incinerator capability around 400kgs every day, change to capacity each hour is approximately 30-40 kgs per hour. According the performance time every day, waste material, funding, growth, etc, you may use capacity from 30-50 kgs each hour incinerator. *The best way to calculate Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Meeting and Testing A: We provide all files and incinerators simple to setup and functionality. Client can send individuals visit our factory to learn installation and operation. Generally, we don’t send engineer to neighborhood site if not ask. The dispatch cost is extra according to order. The next combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD per year maintenance according version, utilize situation.
One individual can service 02 device incinerators. The team should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand risk of medical waste to safeguard worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items | Specification | ||||
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
Main Product List | Double Combustion Chamber | ||||
Smoke Filter Chamber | |||||
PLC Mode Control Case | |||||
Stainless Steel Chimney | |||||
Italy oil/gas burner: 02 units | |||||
Oil Tank (if oil fuel) |