Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize within this gear? A: This gear to medical waste, pet creature, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of ordinary power.
Clover incinerator utilize time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time to get feeding squander. Actual combustion time daily is around 16 hours. The life of incinerator involving 5-10 year based on utilize.
Ordinarily, we proposition small laboratory, small clinic use capacity under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output around 2kgs per people every day. If there are 200 sickbed in the hospital, that's imply you need one incinerator capacity around 400kgs every day, change to power per hour is approximately 30-40 kgs per hour. Incinerator medical for practice, incinerator medical waste, incinerator news, incinerator of china manufature, incinerator pharma manufacturer waste, incinerator portable suppliers from china, According the operation time every day, waste material, funding, growth, etc, you can use potential from 30-50 kgs each hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators simple to setup and operation. Customer can send people visit our factory to learn installation and operation. Generally, we don’t send engineer to neighborhood website if not request. The dispatch cost is additional based on order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode based on order and model.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD annually maintenance according version, utilize situation.
One individual can service 02 device incinerators. The staff must have basic electrician comprehension to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know threat of medical waste to safeguard worker self with necessary protection element.
Q: The Residency time in combustion chamber A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |