comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe
operation. The chamber and burner shall be designed to maintain a minimum combustion temperature of at least
930 to 980 C (1700 to 1800 F), but shall not to exceed 1150 C (2100 F). The ash-removal system shall consist of, as
a minimum, the direct manual removal into a dry
Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with
powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller
particles.
5.16.2 MEDICAL WASTE INCINERATORS
Medical waste incinerators shall be specifically designed by the manufacturer to dispose of all medical wastes. All
units shall be designed for 8 hours
per day of continuous operation and be rated in quantity per hour (i.e. kg/hr or lbs/hr).
Incinerator loading or charging of medical waste shall be batched-fed manually.
Primary combustion chamber shall be the stationary fixed-hearth (or kiln), multiple-chamber, retort type or larger
capacity rotary-hearth (or kiln) type. Burner and combustion air controls shall be fully automatic comprising of, as a
minimum, electronic ignition and all necessary interlocks and safety devices to provide safe operation. The