Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
HIGH TECH PYROLYTIC MEDICAL WASTE HEATER
NB.; Civil tasks as well as any sort of other pertinent alternatives for the setup along with training of drivers need to be included from the furnace ’s rate.
Requires for the refuge of this burner:
Residence of this incinerator comprehensive in provide (your residence have to have toilet as well as hand cleaning facilities as well as likewise firefighting). The measurement of the shelter will judge 4 meter by 6 meter and will be given with appropriate air ventilation.
This substance along with equipment should comprise in the shed of this heater: construction in debris stone, isolation roofing covering versus humudity; altitude with block of 20 centimeters (bloc concrete), moving lintel (linteau) in strengthened concrete; steel frame (charpente en steel); roofing covering in sheet B.C.A. 28 BG
23. Release Requirement Compliance: BS 3316 or similar standard
23. Capability to treat Plastic: Not a lot less than 40 percent by weight
* Frontage of filling door seals increased on hinges, wheel of screw plug, flexible joint, as well as also.
Flame, lighting as well as likewise safety and security and security of electronic ignition, irreversible air flow, electro-magnetic sluice.
* A sheath of emptying of these gases charred.
2. It needs to possess the capability to run really bit less than 10 hours/day
Skill of damages from weight: 60 Kg/h.
* Heating unit with gasoline, mono-bloc distributing directing kind with directly fire, lighting as well as also security of.
Temperature level outside sheet steel.
* A switch breaker for each and every motor (heaters and ventilators).
8. It should be able to hold exhaust in the 2nd shed with gasoline residence of not much less than 2 secs.
Electronic ignition, long-term ventilation, electromagnetic sluice entryway of guideline and also dividing.
> Nature: Calcium silicate. * Heating system of lighting of waste, with gasoline, conventional mono-bloc spreading leading plunging.
burner.
23. The setup burner has to birth a 1 year guarantee.
* Framework of this refractory;
19.
20.
* Electro-ventilator spreading the additional atmosphere, the quality of this atmosphere flow being.
> Thickness: > 150 mm.
The provider will surely perforn an onsite installation of this heater.
5. PYROLYTIC” burning, by managing the gasification of waste.
Tons.
– – Shield in fibrous panel.
Using “PYROLYTIC” combustion should have:.
* A timer with adjustable temporization for the coverage of every heating apparatus.
– – Refractory concrete:.
> Thickness: > 100 mm”.
15. Fuel: diesel.
Boost Immune system: Scruber to be mentionned as discretionary
23. Release Criteria Conformity: BS 3316 or similar standard
23. Capability to deal with Plastic: Not a lot less than 40 percent by weight
24.
loadings.
* A gadget of shot air allowing a whole recombustion of gases,.
14. Heating system process need to be Automatic On/Off.
3.
* The insulating material of the burning chamber has to be composed of refractory bricks,.
Accomplished by valves along with adhering to the constraint of the automatic cycle. Controls along with guidelines:.
– > Nature: 42 percent of A1203.
13.
– – Refractory concrete:.{
(adsbygoogle = window.adsbygoogle || []).push({});|}{
(adsbygoogle = window.adsbygoogle || []).push({});|}
>> Nature: 65 percent of A1203.
Having a high substance of aluminum and additionally protects obstructs so as to make sure that the minimum.
4. Layout Specification: Types A, B, C, D, along with E of medical waste.
* Framework of this refractory;.
* Carcass in solid sheet steel with help of link.
16. The supplier should offer needed details to your absolute best of this installation This incinerator.
– Safeguard in coarse panels:.|* A gadget of air inlet of cooling of waste gases,.
Tons.
– Safeguard in coarse panels:.
19.
20.
15. Fuel: diesel.
The provider will surely perforn an onsite installation of this heater.
* The insulating material of the burning chamber has to be composed of refractory bricks,.
Skill of damages from weight: 60 Kg/h.
Having a high substance of aluminum and additionally protects obstructs so as to make sure that the minimum.
* A regulatory authority with look for the warmth of postcombustion.
Accomplished by valves along with adhering to the constraint of the automatic cycle. Controls along with guidelines:.{
(adsbygoogle = window.adsbygoogle || []).push({});|}
11. The Internal size of this Smokeshaft: Ø 400 as well as its elevation: 8 m.
13.
Using “PYROLYTIC” combustion should have:.
– > Nature: 42 percent of A1203.
loadings.
* A heating unit of lighting which the usage is restricted to the ignition of waste.
Control box watertight to grime, such as:.
* Carcass in solid sheet steel with help of link.
* Framework of this refractory;
The p – ashing has to be carried out in lowest degree of the burning chamber or the deashing.
Boost Immune system: Scruber to be mentionned as discretionary
23. Release Criteria Conformity: BS 3316 or similar standard
23. Capability to deal with Plastic: Not a lot less than 40 percent by weight
24.
Packing protecting out of refractor. -.
Flame, lighting as well as likewise safety and security and security of electronic ignition, irreversible air flow, electro-magnetic sluice.
– – Shield in fibrous panel.
* Plate of burning in Carborundum, avoiding the dealing with glass along with slags. A chamber of write-up burning of gases.
* A timer with adjustable temporization for the coverage of every heating apparatus.{
(adsbygoogle = window.adsbygoogle || []).push({});|}
– – Refractory concrete:.
8. It should be able to hold exhaust in the 2nd shed with gasoline residence of not much less than 2 secs.
Electronic ignition, long-term ventilation, electromagnetic sluice entryway of guideline and also dividing.
4. Layout Specification: Types A, B, C, D, along with E of medical waste.
> Thickness: > 75 mm.
* A sheath of emptying of these gases charred.
> Thickness: > 150 mm.
shutoff.
12. The number of the combustion chamber: 1.200 L.
* Flawlessly tight doorway for the hand-operated loading of waste. The filling should certainly be Manual, Establish.
7. It should have the ability to reduce the quantity of wastes by 98%.
6. The burner should protect against the launch of black smoke in addition to fine dust, (Electric) during the.
* A gadget of shot air allowing a whole recombustion of gases,.
* Heating unit with gasoline, mono-bloc distributing directing kind with directly fire, lighting as well as also security of.
2. It needs to possess the capability to run really bit less than 10 hours/day
> Nature: Calcium silicate. * Heating system of lighting of waste, with gasoline, conventional mono-bloc spreading leading plunging.
>> Nature: 65 percent of A1203.
Temperature level outside sheet steel.
* Frontage of filling door seals increased on hinges, wheel of screw plug, flexible joint, as well as also.
> Thickness: > 100 mm”.
9. The incineration must be fully lacking visible smoke along with annoying odours.
>> Thickness: > 85 mm.
5. PYROLYTIC” burning, by managing the gasification of waste.
17. A burning chamber of waste.
burner.
Trash Incinerators
We are china incinerator maker, service provider and also exporter. Supplier clear up rate for incinerator consumer, supply clinical incinerator, medical facility burner, animal incinerators, hog burners, animal cremation equipment, little burner, pet dog incinerator, pet burner, portable incinerator, small pet incinerator, contagious waste pyrolysis machine, laboratory burner. HICLOVER aid customer lower acquisition budget plan, personalized made feature, top quality products as well as pleasant service.Best incinerator producers, Incinerator companies, community waste incinerators, gas burners, bio medical waste incinerator
animal incinerator china
Medical Waste Shredder
Capacity: Should be 150 liters.
Should be capable to shred up to 100 liters of the treated waste.
7
The technology should be capable to treat hospital waste including sharps like needles,
lancets, scalpels and soft materials like bandages.
Must render the waste to be unrecognizable.
Following accompanying documents must be supplied with the treatment system and shall
be available at the Site:
- Operation instructions (including process description.
- Loading and maintenance procedures.
- Short-form of operation and loading procedures.
- ASTM International (ASTM):
C401 91 (2005) Standard Classification of Alumina and Alumina-Silicate Castable Refractories
C612 04 Mineral Fiber Block and Board Thermal Insulation
- National Fire Protection Association (NFPA):
70 07 National Electrical Code
82 04 Incinerators and Waste and Linen Handling Systems and Equipment
- Underwriters Laboratories (UL):
50 07… Enclosures for Electrical Equipment
PART 2 PRODUCT
2.1 INCINERATOR INSTALLATION
- The incinerator shall consist of a low temperature carbonizing changer (primary chamber) in which the waste
components are converted into gas by heat which is produced through incomplete combustion as the result of a deficiency
of air, and a gas reactor (thermal reactor) in which the gas is burned with a controlled excess of air.
Dual Chamber Incinerator available for sale 50-200kgs per hr( in supply).

Secret Product Listing per 01 collection |
Trick Burning Chamber |
Secondly Burning Chamber |
|
Smoke Filter Chamber |
|
Incinerator PLC Control Situation |
|
Smokeshaft:10.0 Meters *( upgrade to Stainless-steel, cost-free price) |
|
Italy oil/gas burner: 02 devices |
|
Oil Container (if oil gas): 300Liters |

![]()
Items/Model
TS150( PLC)
Idea
Waste Incineration Therapy
Shed Rate
Criterion 50/100/150/ 200 kg/hour
Feed Capability
Average 750kg/feeding
Control Establishing
PLC( Programmable Thinking Controller Incinerator)
Combustion Chamber
1570L
Internal Dimensions
150x100x105cm
Second Chamber
750L
Smoke Filter Chamber
Yes
Feed Setting
Manual
Voltage
210/230V 50/60Hz
Power
0.9 Kw
Oil Usage (kg/hour)
Ordinary 20.4( D.O)
Thermal ability( kw/hour)
166-332
Gas Use (m3/hour)
***
Temperature Level Show
Digital Existing
Temperature Protection
Yes
Oil Storage Tank
300L
Feed Door
80x60cm
Smokeshaft
10Meter
Smokeshaft Kind
Stainless-steel
1st. Chamber Temperature Level
800 ℃–– – – -1000 ℃
secondly. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
8500kg
Exterior Dimensions
300x160x280cm( without smokeshaft)
Incinerator
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize in this gear? A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t indicate any waste material. The animal/pet combustion rate around 2/3 of ordinary capacity.
Clover incinerator utilize time daily to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time incinerator furnace manufacturer, incinerator hospital price, incinerator in hospital, incinerator maker in shanghai, incinerator manufacturers in usa, and time for feeding waste. Actual combustion time daily is about 16 hours. The life of incinerator between 5-10 year according to utilize.
Ordinarily, we proposition small laboratory, small clinic use capacity under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output capacity around 2kgs per individuals per day. If there are 200 sickbed at the clinic, that's imply you need 1 incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the performance time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs each hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Meeting and Testing A: We supply all files and incinerators simple to setup and functionality. Customer can send individuals visit our factory to find out operation and installation. Generally, we don’t send engineer to local site if not ask. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi degree. PLC mode according to model and order.
One person can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know risk of medical waste to safeguard worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |