SUPPLY AND DELIVERY OF INCINERATOR

bacteria incinerator, animal incinerator bid, animal incinerator design, batch burners incinerators,

Category:

Description

 

Description   Minimum Requirements
Design standard Multiple chamber incinerator to the design of EPA   standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:

  • Length
  • Width
  • Height
  • Extra width for burners
At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rake

 

 

 

 

 

 

 

Material of construction
  • Case – 5mm mild steel.
  • Bracing – Heavy angle and channel.
  • Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
  • Ashing door – High grade cast iron.
  • Loading door – 5mm mild steel lined with 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory concrete:

  • Alumina content of refractory
  • Refractory thickness
 

  • Minimum 49%
  • At least 127mm.
Insulation to walls 1000⁰C Castable insulation
Chimney stack:

  • Chimney
  • Height from base
  • 5 mm mild steel
  • 9 meters above ground level and clear the highest point of the building by not less than 3 meters
  • At least 560mm
  • At least 750Kg
Controls:

Draught

 

Air supply

 

Electric

 

 

  • Barometric indicator, door operated draught limiter

 

  • Built-in forced heated air ducts, primary and secondary (intensifier)
  • Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required 415 Volts Three phase.
Auxiliary fuel Electrically operated only
Emission Multiple chamber design with inbuilt emission control
Paint: Case and stack 400⁰C Heat Resistant Grey
Temperature of case 100⁰C