chinese incinerator manufacturers


In a simple design with a metal steel drum electric. including:
A cage for receipt of biomedical waste;
A combustion chamber with fireplace with a filter to retain ashes;
A cover;
An air supply;
A turbine  allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories
Supply of incinerator model PDR-18 with:

·        Capacity 100 kg/hr of waste containing up to 85% moisture

?      Two combustion chambers

·        Two fully automatic, oil fired, pressure jet burners

·        Panel board

·         Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
Type: for animals waste
Capacity: 30 kg per hours for a maximum load of 120 kg.
GLP Gas
Voltage: 110V-120V
Semiautomatic control board
Stainless steel chimney, 3.5 meters above the incinerator.
High temperature painting for all the incinerator.
Front door for loading and unloading.
Fuel    Diesel Oil 8/ kerosene
Capacity (m3)    0.57
Ave Capacity    50 kg per hour
Ave time for Burnout     5 hrs
External Dimensions
Length    2000mm
Width    1100mm
Height including flue    3500mm
Door opening
Internal Dimensions
(primary chamber)
Length    1200mm
Width    620mm
Height     660mm
Operation
Min. operating temperature    9500C
Max. operating temperature    13200C
Residency time in second chamber    2.0 seconds
Weight    1850kgs
Ancillaries
Operating and maintenance manuals
Recommended Spare list
300 liter fuel tank
Plant burning rate – 100kg/hr

Fuel – Diesel oil   – 35 sec Redwood

Overall dimensions are as follows:

Width    2261mm

Length  3264mm

Chimney Diameter  –  390mm

Chimney Height      –  8000mm
chinese incinerator manufacturers, We process 8-10 ton waste of sheep carcass and its byproduct per day. We are looking for the equipment: combustion burners(combined fuel supply:natural gas and diesel),control panel and filter system. The diameter of the incinerator is 20 cm. Lower calorific power of the waste is 4KW/KG. Heating power 4000KW


crematorium manufacturers


Doors

The doors shall be hinged on the right hand side and can be easily opened and closed. All doors shall be manually

operated. Incinerator shall NOT incorporate automatic doors. All doors should be internally lined with pre-determined

thickness insulation and refractory cement.

 

Stack

The stack shall be fabricated from pre-determined thickness stainless steel plate suitably flanged for connection.

 

Combustion Air Blower

A combustion air blower shall be of steel construction type with built-in air damper regulation shall be provided. The

impeller shall be of the radial blade design and all rotating elements shall be dynamically balanced.

 

Burners

Burners fitted shall be of packaged fuel oil fired types. Primary chamber shall be fitted with an on/off type burner

while the secondary chamber shall be fitted with a high/low type burner. The burners shall each have a maximum rating

of300,000 kJ/hr.

 

Controls

A control system shall be provided to control all functions of the primary and secondary chambers including combustion

air distribution and burner control. It shall comprise of PLC, temperature controllers, timers, relays and switches to

provide automatic operation of the entire system. All switches and controls shall be mounted in an IP 55 rated control

panel.

 

Power Supply

The incinerators shall have a power supply of 240/415 volts, 50 Hz AC. All electrical works shall conform to SAA Wiring

Rules SA 3000 and be subject to PNG Power regulations.


professional waste heater



medical waste incinerator: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
Especifica??es Gerais     6 mm plate steel sheel construction
11cm 1400°C refractory Liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000°C
400°C silicone Based finish paint
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1.36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service     220/50
System weight    5,700kg
Dimension “D”    152cm
Doad port height e    60x60cm
Ash port height e    36x36cm
General Specifications    6mm plate steel sheel construction
11cm 1400 ° C refractory liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000 ° C
400 ° C silicone based paint finish
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1:36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000 btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service    220/50
System weight    5.700 kg
Dimension “D”    152cm
Doad port height and    60x60cm
Ash port height and    36x36cm
medical, hospital, veterinary and industrial wastes by medical waste incinerator Process.
So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus.



hog insinerators


Finish

All equipment shall be painted with a coat of zinc rich primer and two coats of high temperature heat resistant

polyurethane type paint. All painted surfaces shall be prepared by either steel shot cleaning or sand blasting.

 

Identification and Name Plates

Identification and name plates containing the manufacturer’s name, model number, serial number, and other pertinent

information shall be securely fastened to the unit in readily visible locations.

 

Fuel Type and Tank

All burners shall be fuel oil (diesel) fired. For all incinerators fitted with fuel oil (diesel) type burners, the

bidder shall supply and install 1000 litres steel tank and all the necessary piping and fittings and initial supply of

1000 litres fuel oil. Where existing fuel is found to be still in good condition from site inspection, contractors must

use existing tanks and therefore must clearly specify in their bids of such usage. The tank shall be positioned at

least 2 meters above ground on steel frame next to the incinerator shed. Fuel delivery to incinerator burners shall be

by gravity feed. The tank should be fitted with a drain plug as standard.

  1. Post – combustion chamber:

Medical waste incinerator

Standard requirement:

The medical incinerator should meet the European standards 2000/76/EC.

Basic requirements:

1-Capacity 100kg/hr.

2-Work for 24 hours.

3-Unit should have enough combustion room consists of two combustion chambers (mounted vertically)

4- Unit should supply with control methods for air entry to the primary and secondary chambers and hence incineration

of the waste is accomplished.

5-The unit charging is done automatically and have an option to be done manually.

6-The ash removal is done automatically and have an option to be done manually

7-The unit should have a dry filtering unit.

8-The unit should be controlled from the control panel.

control panel :

Should show different tasks of operation using (PLC)

-Temperature in combustion chamber

-time of operation and combustion.

-different pressures.

-amount of air in combustion.

-efficiency indicator.

-emergency system in case of increasing pressure or temperature.

f- Time for gas passing:

Minimum time required for passing to combustion chamber for oxidizing 0.5 seconds at 800 degree Celsius .

1- design details:

A-primary combustion chamber:

Oxidize all waste to combustion residuals and temperature not less than 800 degree Celsius.

b- Secondary chamber:

Continue combusting combustion gas residuals and hanging particles using additional burner temperature not less than

1100 degree Celsius and this conditions is reached by harmonizing between temperature and time of passage to ensure

adequate oxidizing supplying enough air to ensure turbulence of gas all the time this is controlled from control panel.


medical waste diesel incinerator



medical waste diesel heater Burning Cost:47.5–– – – 50kg/hour.
Minimum Operating Temperature level:850 o C( key combustion).
Optimum Operating Temperature level:1450 oC( Afterburner chamber).
Second Burning Capacity: Compulsory.
Thickness Insulation:20 mm High.
Refractory Casting: Minimum 65mm.
Strong refracting lining to hold up against:1500 oC.
Regular burn out time: optimum:3 humans resources.
Fuel type: Diesel.
Gas Consumption in L/hr:7.5 to 9.
Home time in additional chamber:2 sec.
Residue ash article 100kg: Max 3.8 kg.
Gizmo for safeguarding versus communicable spatter and/or cross-contamination by securely disinfecting needles, rings, and more by infrared warmth.
Electric characteristics.
1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 kind.
2) Defenses versus over-voltage and over-current line problems.
3) Conformity with relevant Haitian standards as well as regulations.

Operational qualities.
4) Quick complete sanitation in around 5-7 s.
5) Completely separated quartz/ceramic tube, to give safety and security for the person (no open flame).
6) Operating temperature level around 820 ° C.
7) Placed on a steady base, as per instance listed below.



waste heater suppliers from china



Incinerate: medical waste as well as additionally basic waste Capability to melt waste:
400-500kg/ human resources.
Gas: Diesel.
Gas Consumption: 10 liters/hr optimum.
Incineration temperature: 950-1300 levels centigrade.
Case: thick (mins 5mm) stainless-steel covering as well as absolutely safeguarded to.
stand up versus sea humidity Voltage 220/240v or 380/415V Uniformity 50Hz.
high-capacity, powerful, European Requirement heater, ideal for high quantity incineration, with indispensable after-burner for higher performance in addition to exhausts manage.
Waste Type as well as Melt Rate.
Made specifically for usage by fowl farmers,.
lamb farm owners, abbatoirs along with for pet dog.
cremation. The heater will certainly lose approximately 50kg of.
waste per hour (as long as 150kg shed.
Building and construction.
Light steel bonded construction having sheet steel.
As structural area sustains.
Cellular cellular lining.
Monolithic premium quality refractory concrete with high grade insulation support.
Heating units.
Absolutely automated, high-efficiency burners with electronic ignition, flame recommendation as well as burning control devices fitted.
Packing– – Ash elimination.
Hands-on ash removal from the key chamber. (Ash doors are readily offered as needed).
Outside finishing.
Multi-coat premium quality, high-temperature aluminium enamel leading layer paint, finished in silver.
Control.
Completely automated sequential control given by interior.
waste heater manufacturers from china, PLC system providing control of:.
1. Extra chamber pre-heat.
2. Lost cycle (variable).
3. Great cycle.
Fuel Options.
Diesel, LPG, Natural or Biography Gas.
Regular Gas Intake.
Diesel: 8/ 10 litres per hr.
Fluid Gas Gas: 6/ 8 litres per hr.
Gas: 7/ 9 Nm3 per hour.
Electrical supply.
240volt 16 amp.
Secret Requirements.
Chamber Amount 2.38 m3:.
2.2 m (l) x 0.9 m( w) x 1.2 m( h).
Lots Capability approximately 1000kg.
Heaps Technique Top. · Kind: Pyrolytic

· Usage: For medicines

· With Chassis to be Placed in truck/lorry

· May have a main along with added combustion chamber

· Should have a dilution chamber

· Capability: 100 Kgs per hr

· Resource Of Power: Diesel or Natural Gas or Liquified Gas



hospital incinerator manufacturers


The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated.
At first output waste from petrochemical collects and transfers to transit and sorting center in various forms. Input feeds of incinerator plant are shown in below table:

hospital incinerator manufacturers, Waste streams of petrochemical unit collect and store in Transit and Sorting Center.
In Transit and Sorting Center one laboratory must be considered.
In this center, waste will be classified in two groups:
–    Unsuitable for burning
–    Suitable for burning
Unsuitable waste for burning can be divided into the 4 categories:
–    Buried materials
–    Materials (wastes) that need to be stabilized before buried
–    Materials (wastes) that can be sold.
–    Wastes that can be returned to petrochemical.
Suitable wastes are classified into the two categories:
–    Input wastes to rotary kiln, consist of solids and waste fluids.
–    Input wastes to static kiln, consist of clean fluids and gasses.
All solid wastes must be transferred to storage pit from Transit and Sorting Center. Solid wastes storage pit is input of rotary kiln.
All fluid wastes must be stored and stabilized in Transit and Sorting Center. All storage and stabilization devices or facility must be considered. Storage and stabilization devices (facility) consist of:
Tanks, Pumps (Transfer, Loading & Unloading), Agitator (Mixer), Blanketing System, Flare system, Instrumentation and Control Systems, etc
Storage and stabilization capacity must be considered based on worst case (shut down).
Generally incinerator plant consists of two similar trains (capacity of each train is 100%). Each train consists of a rotary kiln and a static kiln.


burner for professional waste



MINIMUM CRITERIA FOR ENGINE OF INCINERATION
CAPACITY OF INCINERATION 30KG/ H

1. BASIC SPECS:

The burner for clinical waste need to be designated for the damages of all sort of waste created by the Facility for Health (waste type medical facility, center, medical lab for ruining ability of 30kg/ h).

Pyrolytic gasification combustion control shall:

? Protect against advancement of black smoke as well as also dirt development point loading of waste;
? Supply normal and complete burning of the waste;
? Provide controlled assuring the absence of color, cloud of smoke or shedding smell;
? Allow limited gas intake

The incinerator with pyrolytic combustion have to have:

a. Combustor:

– – – – Chamber solid steel assistance legs sheet;
– – – – The cellular lining is made from refractory blocks as well as likewise a thermal insulation making sure a minimum temperature of the sheet;
– – – – The sole burning is comprised of a refractory lining particularly created to satisfy the thermal, mechanical in addition to corrosive fluid waste needs and liquified glass;
– – – – The dimensions of the floor are prepared laterally primary air nozzles that sustain burning;
– – – – The fireplace is outfitted with a blending system of waste burning is regulated button;
– – – – The recovery procedure of the ashes will certainly take place daily line before starting the day’s procedure.

Framework of the refractory cellular lining:
* Insulation:
– – – – Operating temperature degree: 1000 ° C max
– – – – Nature: Calcium Silicate – – – Thickness: 80 mm * Refractory: – – – Running temperature: 1650 ° C max – – – Nature: Refractory blocks with 42 alumina – – Density: 110mm

Heater burning:

– – The burning chamber is geared up with a heater to line to make certain right temperature degree for the general damages of waste burning; – – Automatic monobloc burner and also fire dive provided with an electronic ignition system and likewise irreversible air circulation. Air follower: – – A major air and also second air follower gives the needed oxygen shipment – – There is an electrical motor ran shutoff that regulates the blood circulation according to the combustion. – – The stress and anxiety of the fan is 500 mm CE to pierce the mass of – waste throughout burning.

b. Article – – burning chamber:

– Manage the gas has a marginal temperature degree of 1100 ° C with a minimal residence time of 2 secs the afterburner is to; – – An additional air injection is expected in addition to offers best oxygen material; – – The heater ensures a minimum temperature of 1100 ° C continuous; – – The design of this heating system looks like shedding burners; – – The afterburner is – outfitted with accessibility doors in order to ensure typical cleansing– – of dust; – The afterburner is lined with high thermal insulation with a density of 150 mm

c. Closet, control and likewise guideline: – – The entire installation will certainly adapt European criteria( EU ). – – The electrical power is 220V 50Hz singular phase. – – Regulatory authorities of temperature with digital display screen:.
––? 1 to take care of the temperature level of the burning chamber.? 1 for regulating the temperature level of the afterburner.
? The hands-on controls are supplied on each thing.

2. PRODUCT DIMENSIONS

Recap Dimensions. Gas diesel oil.
Amount of combustion

chamber Burning: 0.3 m3.
‘ TEMPERATURE LEVEL LEVELS:. Burning. Afterburner

0.11 KW.
0.11 KW0

Follower power 0.37 kW